Review




Structured Review

Nissui Pharmaceutical physiological phosphate buffer
Physiological Phosphate Buffer, supplied by Nissui Pharmaceutical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/physiological+buffer/physiological+phosphate+buffer/us09504737-339-20-24
Average 90 stars, based on 1 article reviews
physiological phosphate buffer - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

Purification:

Article Title: Immunity-inducing agent
Article Snippet: The buffer of the purified preparation obtained by the above method was replaced with a reaction buffer (50 mM Tris-HCl, 100 mM NaCl, 5 mM CaCl2 (pH8.0)), and the resulting sample was subjected to cleavage of the His tag with factor Xa protease and purification of the protein of interest, using Factor Xa Cleavage Capture Kit (manufactured by Novagen) in accordance with the protocol attached to the kit. .. Subsequently, the buffer of 12 ml of the purified preparation obtained by the above method was replaced with a physiological phosphate buffer (manufactured by Nissui Pharmaceutical) using ultrafiltration NANOSEP 10K OMEGA (manufactured by PALL), and the resulting sample was subjected to aseptic filtration through HT Tuffryn Acrodisc 0.22 μm (manufactured by PALL) and used in the experiment. (3) Anti-Tumor Effect of Recombinant Murine PDS5A Protein in Tumor-Bearing Mouse The murine neuroblastoma cell line N2a was subcutaneously transplanted to A/J mice (7 weeks old, male, purchased from Japan SLC) in an amount of 1×106 cells. ..

Article Title: Immune response inducer
Article Snippet: The buffer contained in the purified preparation obtained by the above-described method was replaced with a reaction buffer (50 mM Tris-HCl, 100 mM NaCl, 5 mM CaCl2; pH8.0), and cleavage of His tag by Factor Xa protease and purification of the protein of interest were carried out, using Factor Xa Cleavage Capture Kit (manufactured by Novagen), in accordance with the protocols attached to the kit. .. Subsequently, the buffer contained in 1.2 ml of the purified preparation obtained by the above-described method was replaced with physiological phosphate buffer (manufactured by Nissui Pharmaceutical) by ultrafiltration using NANOSEP 10K OMEGA (manufactured by PALL), and the resulting solution was filtered aseptically using HT Tuffryn Acrodisc 0.22 μm (manufactured by PALL) and used in the following experiments. ..

Filtration:

Article Title: Immunity-inducing agent
Article Snippet: The buffer of the purified preparation obtained by the above method was replaced with a reaction buffer (50 mM Tris-HCl, 100 mM NaCl, 5 mM CaCl2 (pH8.0)), and the resulting sample was subjected to cleavage of the His tag with factor Xa protease and purification of the protein of interest, using Factor Xa Cleavage Capture Kit (manufactured by Novagen) in accordance with the protocol attached to the kit. .. Subsequently, the buffer of 12 ml of the purified preparation obtained by the above method was replaced with a physiological phosphate buffer (manufactured by Nissui Pharmaceutical) using ultrafiltration NANOSEP 10K OMEGA (manufactured by PALL), and the resulting sample was subjected to aseptic filtration through HT Tuffryn Acrodisc 0.22 μm (manufactured by PALL) and used in the experiment. (3) Anti-Tumor Effect of Recombinant Murine PDS5A Protein in Tumor-Bearing Mouse The murine neuroblastoma cell line N2a was subcutaneously transplanted to A/J mice (7 weeks old, male, purchased from Japan SLC) in an amount of 1×106 cells. ..

Recombinant:

Article Title: Immunity-inducing agent
Article Snippet: The buffer of the purified preparation obtained by the above method was replaced with a reaction buffer (50 mM Tris-HCl, 100 mM NaCl, 5 mM CaCl2 (pH8.0)), and the resulting sample was subjected to cleavage of the His tag with factor Xa protease and purification of the protein of interest, using Factor Xa Cleavage Capture Kit (manufactured by Novagen) in accordance with the protocol attached to the kit. .. Subsequently, the buffer of 12 ml of the purified preparation obtained by the above method was replaced with a physiological phosphate buffer (manufactured by Nissui Pharmaceutical) using ultrafiltration NANOSEP 10K OMEGA (manufactured by PALL), and the resulting sample was subjected to aseptic filtration through HT Tuffryn Acrodisc 0.22 μm (manufactured by PALL) and used in the experiment. (3) Anti-Tumor Effect of Recombinant Murine PDS5A Protein in Tumor-Bearing Mouse The murine neuroblastoma cell line N2a was subcutaneously transplanted to A/J mice (7 weeks old, male, purchased from Japan SLC) in an amount of 1×106 cells. ..



Similar Products

97
Thermo Fisher physiologic buffer solution
Physiologic Buffer Solution, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/physiological+buffer/Buffer+solution+pH+7%2C+Phosphate+buffer/pmc13080204-38-34-51
Average 97 stars, based on 1 article reviews
physiologic buffer solution - by Bioz Stars, 2026-11
97/100 stars
  Buy from Supplier

86
Merck & Co physiological buffer solution
Experimental set-up for irradiation and OCT-imaging of the murine Arteria saphena. A For irradiation in the X-ray device (1), anesthetized animals were positioned on their left side and secured on a Plexiglas holder. The bent right leg and lower abdomen were shielded with lead to protect them from radiation, ensuring that only the inner side of the left lower leg remained within the irradiation field. The exposure area beneath the irradiation window was defined by a collimator plate made of a bismuth-lead-tin alloy (MCP-96) with copper cutouts (2). Up to five animals were irradiated simultaneously on an underlying Plexiglas plate (3). The mesures are given in centimeters. B The OCT system for vascular imaging of the A. saphena operates using near-infrared light emitted by a diode (1), which is transmitted to the scanner head (2) via fiber optic cables (3). Within the scanner head the incoming light is collimated to a beam of 2.4 mm in diameter through a collimator (4) (focal length = 12 mm) and subsequently divided into a reference and probe beam of equal diameter with a beam splitter. To scan the arterial surface, the probe beam is diffracted via two galvanometric scanners (5) (Cambridge Technologies, Planegg) and focused through an achromatic lense (6) (focal length = 25.4 mm, diameter = 15 mm). The light reflected by the arterial surface and the reference beam that has been reflected by a mirror are then recombined by the beam splitter. Fiber optic cables lead the resulting interference signal through a collimator (focal length = 40 mm) and to a spectrometer to be spectrally analyzed with a diffraction grating (1200 lines/mm). The interference spectrum is then focused through an achromatic lense (focal length = 75 mm) and detected with a silicon detector (LIS-1024, pixel size: 7.8 μm × 125 μm × 1024 px, Photon Vision Systems Inc., Homer, USA). A Fast Fourier Transform of the interference signal provides depth-resolved information about the arterial tissue. C Representative recording of the A. saphena (white arrows) and Vena saphena medialis (grey arrows) of a C57BL/6 mouse aged 8 weeks, one day after irradiation with 2 Gy. The upper picture row in the foreground represents 2-D cross sectional OCT-images. The picture row below in the background are video-recordings to orientate on the tissue. Left: Vessel diameter at rest after application of <t>physiological</t> buffer solution. Middle: Arterial vasoconstriction (VC) after application of buffer solution with high potassium concentration (K+). Right: Arterial vasodilation (VD) induced by sodium nitroprusside (SNP). The diameter of the saphenous vein was unaffected. Below: Time course of inner diameter changes of A. saphena with fitted sigmoid function (black line). d0: initial diameter, dVC: minimal diameter during VC. dVD: maximal diameter during VD. t 1/2 : time of half VC or VD
Physiological Buffer Solution, supplied by Merck & Co, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/physiological+buffer/buffer+solution/pmc12538826-77-15-27
Average 86 stars, based on 1 article reviews
physiological buffer solution - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

90
Beijing Solarbio Science physiological phosphate buffered saline (pbs) solution
Experimental set-up for irradiation and OCT-imaging of the murine Arteria saphena. A For irradiation in the X-ray device (1), anesthetized animals were positioned on their left side and secured on a Plexiglas holder. The bent right leg and lower abdomen were shielded with lead to protect them from radiation, ensuring that only the inner side of the left lower leg remained within the irradiation field. The exposure area beneath the irradiation window was defined by a collimator plate made of a bismuth-lead-tin alloy (MCP-96) with copper cutouts (2). Up to five animals were irradiated simultaneously on an underlying Plexiglas plate (3). The mesures are given in centimeters. B The OCT system for vascular imaging of the A. saphena operates using near-infrared light emitted by a diode (1), which is transmitted to the scanner head (2) via fiber optic cables (3). Within the scanner head the incoming light is collimated to a beam of 2.4 mm in diameter through a collimator (4) (focal length = 12 mm) and subsequently divided into a reference and probe beam of equal diameter with a beam splitter. To scan the arterial surface, the probe beam is diffracted via two galvanometric scanners (5) (Cambridge Technologies, Planegg) and focused through an achromatic lense (6) (focal length = 25.4 mm, diameter = 15 mm). The light reflected by the arterial surface and the reference beam that has been reflected by a mirror are then recombined by the beam splitter. Fiber optic cables lead the resulting interference signal through a collimator (focal length = 40 mm) and to a spectrometer to be spectrally analyzed with a diffraction grating (1200 lines/mm). The interference spectrum is then focused through an achromatic lense (focal length = 75 mm) and detected with a silicon detector (LIS-1024, pixel size: 7.8 μm × 125 μm × 1024 px, Photon Vision Systems Inc., Homer, USA). A Fast Fourier Transform of the interference signal provides depth-resolved information about the arterial tissue. C Representative recording of the A. saphena (white arrows) and Vena saphena medialis (grey arrows) of a C57BL/6 mouse aged 8 weeks, one day after irradiation with 2 Gy. The upper picture row in the foreground represents 2-D cross sectional OCT-images. The picture row below in the background are video-recordings to orientate on the tissue. Left: Vessel diameter at rest after application of <t>physiological</t> buffer solution. Middle: Arterial vasoconstriction (VC) after application of buffer solution with high potassium concentration (K+). Right: Arterial vasodilation (VD) induced by sodium nitroprusside (SNP). The diameter of the saphenous vein was unaffected. Below: Time course of inner diameter changes of A. saphena with fitted sigmoid function (black line). d0: initial diameter, dVC: minimal diameter during VC. dVD: maximal diameter during VD. t 1/2 : time of half VC or VD
Physiological Phosphate Buffered Saline (Pbs) Solution, supplied by Beijing Solarbio Science, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/physiological+buffer/phosphate+buffered+saline++pbs+/pm40623971-196-2-15
Average 90 stars, based on 1 article reviews
physiological phosphate buffered saline (pbs) solution - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

99
Malvern Panalytical physiological buffer
Experimental set-up for irradiation and OCT-imaging of the murine Arteria saphena. A For irradiation in the X-ray device (1), anesthetized animals were positioned on their left side and secured on a Plexiglas holder. The bent right leg and lower abdomen were shielded with lead to protect them from radiation, ensuring that only the inner side of the left lower leg remained within the irradiation field. The exposure area beneath the irradiation window was defined by a collimator plate made of a bismuth-lead-tin alloy (MCP-96) with copper cutouts (2). Up to five animals were irradiated simultaneously on an underlying Plexiglas plate (3). The mesures are given in centimeters. B The OCT system for vascular imaging of the A. saphena operates using near-infrared light emitted by a diode (1), which is transmitted to the scanner head (2) via fiber optic cables (3). Within the scanner head the incoming light is collimated to a beam of 2.4 mm in diameter through a collimator (4) (focal length = 12 mm) and subsequently divided into a reference and probe beam of equal diameter with a beam splitter. To scan the arterial surface, the probe beam is diffracted via two galvanometric scanners (5) (Cambridge Technologies, Planegg) and focused through an achromatic lense (6) (focal length = 25.4 mm, diameter = 15 mm). The light reflected by the arterial surface and the reference beam that has been reflected by a mirror are then recombined by the beam splitter. Fiber optic cables lead the resulting interference signal through a collimator (focal length = 40 mm) and to a spectrometer to be spectrally analyzed with a diffraction grating (1200 lines/mm). The interference spectrum is then focused through an achromatic lense (focal length = 75 mm) and detected with a silicon detector (LIS-1024, pixel size: 7.8 μm × 125 μm × 1024 px, Photon Vision Systems Inc., Homer, USA). A Fast Fourier Transform of the interference signal provides depth-resolved information about the arterial tissue. C Representative recording of the A. saphena (white arrows) and Vena saphena medialis (grey arrows) of a C57BL/6 mouse aged 8 weeks, one day after irradiation with 2 Gy. The upper picture row in the foreground represents 2-D cross sectional OCT-images. The picture row below in the background are video-recordings to orientate on the tissue. Left: Vessel diameter at rest after application of <t>physiological</t> buffer solution. Middle: Arterial vasoconstriction (VC) after application of buffer solution with high potassium concentration (K+). Right: Arterial vasodilation (VD) induced by sodium nitroprusside (SNP). The diameter of the saphenous vein was unaffected. Below: Time course of inner diameter changes of A. saphena with fitted sigmoid function (black line). d0: initial diameter, dVC: minimal diameter during VC. dVD: maximal diameter during VD. t 1/2 : time of half VC or VD
Physiological Buffer, supplied by Malvern Panalytical, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/physiological+buffer/PEAQ-ITC/pmc11849797-159-9-13
Average 99 stars, based on 1 article reviews
physiological buffer - by Bioz Stars, 2026-11
99/100 stars
  Buy from Supplier

90
CompTech Computer Technologies gelatin-buffered physiological saline b100
Experimental set-up for irradiation and OCT-imaging of the murine Arteria saphena. A For irradiation in the X-ray device (1), anesthetized animals were positioned on their left side and secured on a Plexiglas holder. The bent right leg and lower abdomen were shielded with lead to protect them from radiation, ensuring that only the inner side of the left lower leg remained within the irradiation field. The exposure area beneath the irradiation window was defined by a collimator plate made of a bismuth-lead-tin alloy (MCP-96) with copper cutouts (2). Up to five animals were irradiated simultaneously on an underlying Plexiglas plate (3). The mesures are given in centimeters. B The OCT system for vascular imaging of the A. saphena operates using near-infrared light emitted by a diode (1), which is transmitted to the scanner head (2) via fiber optic cables (3). Within the scanner head the incoming light is collimated to a beam of 2.4 mm in diameter through a collimator (4) (focal length = 12 mm) and subsequently divided into a reference and probe beam of equal diameter with a beam splitter. To scan the arterial surface, the probe beam is diffracted via two galvanometric scanners (5) (Cambridge Technologies, Planegg) and focused through an achromatic lense (6) (focal length = 25.4 mm, diameter = 15 mm). The light reflected by the arterial surface and the reference beam that has been reflected by a mirror are then recombined by the beam splitter. Fiber optic cables lead the resulting interference signal through a collimator (focal length = 40 mm) and to a spectrometer to be spectrally analyzed with a diffraction grating (1200 lines/mm). The interference spectrum is then focused through an achromatic lense (focal length = 75 mm) and detected with a silicon detector (LIS-1024, pixel size: 7.8 μm × 125 μm × 1024 px, Photon Vision Systems Inc., Homer, USA). A Fast Fourier Transform of the interference signal provides depth-resolved information about the arterial tissue. C Representative recording of the A. saphena (white arrows) and Vena saphena medialis (grey arrows) of a C57BL/6 mouse aged 8 weeks, one day after irradiation with 2 Gy. The upper picture row in the foreground represents 2-D cross sectional OCT-images. The picture row below in the background are video-recordings to orientate on the tissue. Left: Vessel diameter at rest after application of <t>physiological</t> buffer solution. Middle: Arterial vasoconstriction (VC) after application of buffer solution with high potassium concentration (K+). Right: Arterial vasodilation (VD) induced by sodium nitroprusside (SNP). The diameter of the saphenous vein was unaffected. Below: Time course of inner diameter changes of A. saphena with fitted sigmoid function (black line). d0: initial diameter, dVC: minimal diameter during VC. dVD: maximal diameter during VD. t 1/2 : time of half VC or VD
Gelatin Buffered Physiological Saline B100, supplied by CompTech Computer Technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/physiological+buffer/gelatin+veronal+buffer+calcium+magnesium++gvb/pmc11706223-63-18-23
Average 90 stars, based on 1 article reviews
gelatin-buffered physiological saline b100 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

97
Valiant Co Ltd physiological capillary depletion buffer
Experimental set-up for irradiation and OCT-imaging of the murine Arteria saphena. A For irradiation in the X-ray device (1), anesthetized animals were positioned on their left side and secured on a Plexiglas holder. The bent right leg and lower abdomen were shielded with lead to protect them from radiation, ensuring that only the inner side of the left lower leg remained within the irradiation field. The exposure area beneath the irradiation window was defined by a collimator plate made of a bismuth-lead-tin alloy (MCP-96) with copper cutouts (2). Up to five animals were irradiated simultaneously on an underlying Plexiglas plate (3). The mesures are given in centimeters. B The OCT system for vascular imaging of the A. saphena operates using near-infrared light emitted by a diode (1), which is transmitted to the scanner head (2) via fiber optic cables (3). Within the scanner head the incoming light is collimated to a beam of 2.4 mm in diameter through a collimator (4) (focal length = 12 mm) and subsequently divided into a reference and probe beam of equal diameter with a beam splitter. To scan the arterial surface, the probe beam is diffracted via two galvanometric scanners (5) (Cambridge Technologies, Planegg) and focused through an achromatic lense (6) (focal length = 25.4 mm, diameter = 15 mm). The light reflected by the arterial surface and the reference beam that has been reflected by a mirror are then recombined by the beam splitter. Fiber optic cables lead the resulting interference signal through a collimator (focal length = 40 mm) and to a spectrometer to be spectrally analyzed with a diffraction grating (1200 lines/mm). The interference spectrum is then focused through an achromatic lense (focal length = 75 mm) and detected with a silicon detector (LIS-1024, pixel size: 7.8 μm × 125 μm × 1024 px, Photon Vision Systems Inc., Homer, USA). A Fast Fourier Transform of the interference signal provides depth-resolved information about the arterial tissue. C Representative recording of the A. saphena (white arrows) and Vena saphena medialis (grey arrows) of a C57BL/6 mouse aged 8 weeks, one day after irradiation with 2 Gy. The upper picture row in the foreground represents 2-D cross sectional OCT-images. The picture row below in the background are video-recordings to orientate on the tissue. Left: Vessel diameter at rest after application of <t>physiological</t> buffer solution. Middle: Arterial vasoconstriction (VC) after application of buffer solution with high potassium concentration (K+). Right: Arterial vasodilation (VD) induced by sodium nitroprusside (SNP). The diameter of the saphenous vein was unaffected. Below: Time course of inner diameter changes of A. saphena with fitted sigmoid function (black line). d0: initial diameter, dVC: minimal diameter during VC. dVD: maximal diameter during VD. t 1/2 : time of half VC or VD
Physiological Capillary Depletion Buffer, supplied by Valiant Co Ltd, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/physiological+buffer/HEPES/pmc11501026-108-6-56
Average 97 stars, based on 1 article reviews
physiological capillary depletion buffer - by Bioz Stars, 2026-11
97/100 stars
  Buy from Supplier

99
Thermo Fisher hepes buffered physiological saline
Experimental set-up for irradiation and OCT-imaging of the murine Arteria saphena. A For irradiation in the X-ray device (1), anesthetized animals were positioned on their left side and secured on a Plexiglas holder. The bent right leg and lower abdomen were shielded with lead to protect them from radiation, ensuring that only the inner side of the left lower leg remained within the irradiation field. The exposure area beneath the irradiation window was defined by a collimator plate made of a bismuth-lead-tin alloy (MCP-96) with copper cutouts (2). Up to five animals were irradiated simultaneously on an underlying Plexiglas plate (3). The mesures are given in centimeters. B The OCT system for vascular imaging of the A. saphena operates using near-infrared light emitted by a diode (1), which is transmitted to the scanner head (2) via fiber optic cables (3). Within the scanner head the incoming light is collimated to a beam of 2.4 mm in diameter through a collimator (4) (focal length = 12 mm) and subsequently divided into a reference and probe beam of equal diameter with a beam splitter. To scan the arterial surface, the probe beam is diffracted via two galvanometric scanners (5) (Cambridge Technologies, Planegg) and focused through an achromatic lense (6) (focal length = 25.4 mm, diameter = 15 mm). The light reflected by the arterial surface and the reference beam that has been reflected by a mirror are then recombined by the beam splitter. Fiber optic cables lead the resulting interference signal through a collimator (focal length = 40 mm) and to a spectrometer to be spectrally analyzed with a diffraction grating (1200 lines/mm). The interference spectrum is then focused through an achromatic lense (focal length = 75 mm) and detected with a silicon detector (LIS-1024, pixel size: 7.8 μm × 125 μm × 1024 px, Photon Vision Systems Inc., Homer, USA). A Fast Fourier Transform of the interference signal provides depth-resolved information about the arterial tissue. C Representative recording of the A. saphena (white arrows) and Vena saphena medialis (grey arrows) of a C57BL/6 mouse aged 8 weeks, one day after irradiation with 2 Gy. The upper picture row in the foreground represents 2-D cross sectional OCT-images. The picture row below in the background are video-recordings to orientate on the tissue. Left: Vessel diameter at rest after application of <t>physiological</t> buffer solution. Middle: Arterial vasoconstriction (VC) after application of buffer solution with high potassium concentration (K+). Right: Arterial vasodilation (VD) induced by sodium nitroprusside (SNP). The diameter of the saphenous vein was unaffected. Below: Time course of inner diameter changes of A. saphena with fitted sigmoid function (black line). d0: initial diameter, dVC: minimal diameter during VC. dVD: maximal diameter during VD. t 1/2 : time of half VC or VD
Hepes Buffered Physiological Saline, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/physiological+buffer/HEPES/pm39002470-135-13-17
Average 99 stars, based on 1 article reviews
hepes buffered physiological saline - by Bioz Stars, 2026-11
99/100 stars
  Buy from Supplier

90
Merck KGaA physiological phosphate buffer
Experimental set-up for irradiation and OCT-imaging of the murine Arteria saphena. A For irradiation in the X-ray device (1), anesthetized animals were positioned on their left side and secured on a Plexiglas holder. The bent right leg and lower abdomen were shielded with lead to protect them from radiation, ensuring that only the inner side of the left lower leg remained within the irradiation field. The exposure area beneath the irradiation window was defined by a collimator plate made of a bismuth-lead-tin alloy (MCP-96) with copper cutouts (2). Up to five animals were irradiated simultaneously on an underlying Plexiglas plate (3). The mesures are given in centimeters. B The OCT system for vascular imaging of the A. saphena operates using near-infrared light emitted by a diode (1), which is transmitted to the scanner head (2) via fiber optic cables (3). Within the scanner head the incoming light is collimated to a beam of 2.4 mm in diameter through a collimator (4) (focal length = 12 mm) and subsequently divided into a reference and probe beam of equal diameter with a beam splitter. To scan the arterial surface, the probe beam is diffracted via two galvanometric scanners (5) (Cambridge Technologies, Planegg) and focused through an achromatic lense (6) (focal length = 25.4 mm, diameter = 15 mm). The light reflected by the arterial surface and the reference beam that has been reflected by a mirror are then recombined by the beam splitter. Fiber optic cables lead the resulting interference signal through a collimator (focal length = 40 mm) and to a spectrometer to be spectrally analyzed with a diffraction grating (1200 lines/mm). The interference spectrum is then focused through an achromatic lense (focal length = 75 mm) and detected with a silicon detector (LIS-1024, pixel size: 7.8 μm × 125 μm × 1024 px, Photon Vision Systems Inc., Homer, USA). A Fast Fourier Transform of the interference signal provides depth-resolved information about the arterial tissue. C Representative recording of the A. saphena (white arrows) and Vena saphena medialis (grey arrows) of a C57BL/6 mouse aged 8 weeks, one day after irradiation with 2 Gy. The upper picture row in the foreground represents 2-D cross sectional OCT-images. The picture row below in the background are video-recordings to orientate on the tissue. Left: Vessel diameter at rest after application of <t>physiological</t> buffer solution. Middle: Arterial vasoconstriction (VC) after application of buffer solution with high potassium concentration (K+). Right: Arterial vasodilation (VD) induced by sodium nitroprusside (SNP). The diameter of the saphenous vein was unaffected. Below: Time course of inner diameter changes of A. saphena with fitted sigmoid function (black line). d0: initial diameter, dVC: minimal diameter during VC. dVD: maximal diameter during VD. t 1/2 : time of half VC or VD
Physiological Phosphate Buffer, supplied by Merck KGaA, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/physiological+buffer/physiological+phosphate+buffer/pm38723828-91-7-10
Average 90 stars, based on 1 article reviews
physiological phosphate buffer - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Experimental set-up for irradiation and OCT-imaging of the murine Arteria saphena. A For irradiation in the X-ray device (1), anesthetized animals were positioned on their left side and secured on a Plexiglas holder. The bent right leg and lower abdomen were shielded with lead to protect them from radiation, ensuring that only the inner side of the left lower leg remained within the irradiation field. The exposure area beneath the irradiation window was defined by a collimator plate made of a bismuth-lead-tin alloy (MCP-96) with copper cutouts (2). Up to five animals were irradiated simultaneously on an underlying Plexiglas plate (3). The mesures are given in centimeters. B The OCT system for vascular imaging of the A. saphena operates using near-infrared light emitted by a diode (1), which is transmitted to the scanner head (2) via fiber optic cables (3). Within the scanner head the incoming light is collimated to a beam of 2.4 mm in diameter through a collimator (4) (focal length = 12 mm) and subsequently divided into a reference and probe beam of equal diameter with a beam splitter. To scan the arterial surface, the probe beam is diffracted via two galvanometric scanners (5) (Cambridge Technologies, Planegg) and focused through an achromatic lense (6) (focal length = 25.4 mm, diameter = 15 mm). The light reflected by the arterial surface and the reference beam that has been reflected by a mirror are then recombined by the beam splitter. Fiber optic cables lead the resulting interference signal through a collimator (focal length = 40 mm) and to a spectrometer to be spectrally analyzed with a diffraction grating (1200 lines/mm). The interference spectrum is then focused through an achromatic lense (focal length = 75 mm) and detected with a silicon detector (LIS-1024, pixel size: 7.8 μm × 125 μm × 1024 px, Photon Vision Systems Inc., Homer, USA). A Fast Fourier Transform of the interference signal provides depth-resolved information about the arterial tissue. C Representative recording of the A. saphena (white arrows) and Vena saphena medialis (grey arrows) of a C57BL/6 mouse aged 8 weeks, one day after irradiation with 2 Gy. The upper picture row in the foreground represents 2-D cross sectional OCT-images. The picture row below in the background are video-recordings to orientate on the tissue. Left: Vessel diameter at rest after application of physiological buffer solution. Middle: Arterial vasoconstriction (VC) after application of buffer solution with high potassium concentration (K+). Right: Arterial vasodilation (VD) induced by sodium nitroprusside (SNP). The diameter of the saphenous vein was unaffected. Below: Time course of inner diameter changes of A. saphena with fitted sigmoid function (black line). d0: initial diameter, dVC: minimal diameter during VC. dVD: maximal diameter during VD. t 1/2 : time of half VC or VD

Journal: Cardio-oncology

Article Title: Radiation- and age-related vascular dysfunction as an early indicator of cardiovascular risk: a long-term study in the ApoE −/− mouse model of atherosclerosis

doi: 10.1186/s40959-025-00395-6

Figure Lengend Snippet: Experimental set-up for irradiation and OCT-imaging of the murine Arteria saphena. A For irradiation in the X-ray device (1), anesthetized animals were positioned on their left side and secured on a Plexiglas holder. The bent right leg and lower abdomen were shielded with lead to protect them from radiation, ensuring that only the inner side of the left lower leg remained within the irradiation field. The exposure area beneath the irradiation window was defined by a collimator plate made of a bismuth-lead-tin alloy (MCP-96) with copper cutouts (2). Up to five animals were irradiated simultaneously on an underlying Plexiglas plate (3). The mesures are given in centimeters. B The OCT system for vascular imaging of the A. saphena operates using near-infrared light emitted by a diode (1), which is transmitted to the scanner head (2) via fiber optic cables (3). Within the scanner head the incoming light is collimated to a beam of 2.4 mm in diameter through a collimator (4) (focal length = 12 mm) and subsequently divided into a reference and probe beam of equal diameter with a beam splitter. To scan the arterial surface, the probe beam is diffracted via two galvanometric scanners (5) (Cambridge Technologies, Planegg) and focused through an achromatic lense (6) (focal length = 25.4 mm, diameter = 15 mm). The light reflected by the arterial surface and the reference beam that has been reflected by a mirror are then recombined by the beam splitter. Fiber optic cables lead the resulting interference signal through a collimator (focal length = 40 mm) and to a spectrometer to be spectrally analyzed with a diffraction grating (1200 lines/mm). The interference spectrum is then focused through an achromatic lense (focal length = 75 mm) and detected with a silicon detector (LIS-1024, pixel size: 7.8 μm × 125 μm × 1024 px, Photon Vision Systems Inc., Homer, USA). A Fast Fourier Transform of the interference signal provides depth-resolved information about the arterial tissue. C Representative recording of the A. saphena (white arrows) and Vena saphena medialis (grey arrows) of a C57BL/6 mouse aged 8 weeks, one day after irradiation with 2 Gy. The upper picture row in the foreground represents 2-D cross sectional OCT-images. The picture row below in the background are video-recordings to orientate on the tissue. Left: Vessel diameter at rest after application of physiological buffer solution. Middle: Arterial vasoconstriction (VC) after application of buffer solution with high potassium concentration (K+). Right: Arterial vasodilation (VD) induced by sodium nitroprusside (SNP). The diameter of the saphenous vein was unaffected. Below: Time course of inner diameter changes of A. saphena with fitted sigmoid function (black line). d0: initial diameter, dVC: minimal diameter during VC. dVD: maximal diameter during VD. t 1/2 : time of half VC or VD

Article Snippet: To assess the arterial diameter at baseline the exposed A. saphena was moistened with a physiological buffer solution (NaCl: 119 mmol/l, Merck, Darmstadt, Germany; KCl: 4.7 mmol/l, Merck; MgSO 4 : 1.17 mmol/l, Sigma-Aldrich, Taufkirchen, Germany; NaHCO 3 : 25 mmol/l, Merck; KH 2 PO 4 : 1.18 mmol/l, Merck; Glucose: 5.5 mmol/l, Merck; EDTA: 0.027 mmol/l, Prolabo, VWR International, Darmstadt) right before starting OCT. Acquisition of the baseline diameter stopped automatically after 30 initial B-scans (equivalent to a recording time of 7.5 s).

Techniques: Irradiation, Imaging, Concentration Assay