Review




Structured Review

HEKA Electronics Incorporated patchmaster acquisition software
Patchmaster Acquisition Software, supplied by HEKA Electronics Incorporated, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/patchmaster+(heka)+software/acquisition+software+patchmaster/pmc03487033-66-61-59
Average 90 stars, based on 1 article reviews
patchmaster acquisition software - by Bioz Stars, 2026-09
90/100 stars

Images

Related Articles

Software:

Article Title: The F-Actin Binding Protein Cortactin Regulates the Dynamics of the Exocytotic Fusion Pore through its SH3 Domain
Article Snippet: Exocytosis was monitored as previously described ( ) using 5-μm-diameter carbon fibers (Thornel P-55; Amoco, Greenville, SC, USA) and a patch clamp amplifier (EPC-10 USB; HEKA Electronics, Lambrecht, Germany). .. The amperometric signal was low-pass filtered at 1 KHz and digitalized at 10 KHz with the acquisition software PatchMaster (HEKA Electronics, Lambrecht, Germany). ..

Article Title: Identification of a New Exo-Endocytic Mechanism Triggered by Corticotropin-Releasing Hormone in Mast Cells.
Article Snippet: .. The signal was digitized at 4 kHz and filtered with an internal low-pass Bessel filter at 2 kHz with the acquisition software PatchMaster (HEKA Electronics). ..

Article Title: TRPV1 regulates excitatory innervation of OLM neurons in the hippocampus
Article Snippet: .. Recordings were performed with a HEKA EPC10 USB double patch clamp amplifier coupled to Patchmaster acquisition software (HEKA Electronics Inc.). .. Borosilicate glass 2–5 MΩ micropipettes used for recording were pulled using a P-97 micropipette puller (Sutter Instruments).

Article Title: TRPV1 regulates excitatory innervation of OLM neurons in the hippocampus.
Article Snippet: .. Recordings were performed with a HEKA EPC10 USB double patch clamp amplifier coupled to Patchmaster acquisition software (HEKA Electronics Inc.). .. Borosilicate glass 2–5 MO micropipettes used for recording were pulled using a P-97 micropipette puller (Sutter Instruments).

Article Title: An arginine residue in the outer segment of hASIC1a TM1 affects both proton affinity and channel desensitization
Article Snippet: .. Currents were recorded from excised patches in the outside-out configuration using a HEKA patch clamp EPC10 amplifier and PATCHMASTER acquisition software v2 × 90.2 (HEKA Electronic). ..

Article Title: Structural basis for urate recognition and apigenin inhibition of human GLUT9.
Article Snippet: The borosilicate pipettes (Sutter Instrument) had a resistance of 2-4 MΩ and were filled with the internal solution composed of 140mM KCl, 1mM MgCl2, 5mM EGTA, and 10mM HEPES (pH adjusted to 7.4 with KOH). .. Currents were elicited with a voltage step from −30mV to +30mV, using an EPC10-USB amplifier with Patchmaster software v2*90.2 (HEKA Electronic), filtered at 3 kHz (low-pass Bessel filter) and sampled at 50 kHz. ..

Article Title: A valve-like mechanism controls desensitization of functional mammalian isoforms of acid-sensing ion channels
Article Snippet: Psalmotoxin-1 was from Alomone Labs, Tris(2-carboxyethyl)phosphine (TCEP) and other chemicals were from Sigma-Aldrich. .. hASIC1a currents were recorded in excised patches from oocytes in the outside-out configuration using a HEKA patch clamp EPC10 amplifier and PATCHMASTER acquisition software v2 × 90.2 (HEKA Electronic). ..

Patch Clamp:

Article Title: TRPV1 regulates excitatory innervation of OLM neurons in the hippocampus
Article Snippet: .. Recordings were performed with a HEKA EPC10 USB double patch clamp amplifier coupled to Patchmaster acquisition software (HEKA Electronics Inc.). .. Borosilicate glass 2–5 MΩ micropipettes used for recording were pulled using a P-97 micropipette puller (Sutter Instruments).

Article Title: TRPV1 regulates excitatory innervation of OLM neurons in the hippocampus.
Article Snippet: .. Recordings were performed with a HEKA EPC10 USB double patch clamp amplifier coupled to Patchmaster acquisition software (HEKA Electronics Inc.). .. Borosilicate glass 2–5 MO micropipettes used for recording were pulled using a P-97 micropipette puller (Sutter Instruments).

Article Title: An arginine residue in the outer segment of hASIC1a TM1 affects both proton affinity and channel desensitization
Article Snippet: .. Currents were recorded from excised patches in the outside-out configuration using a HEKA patch clamp EPC10 amplifier and PATCHMASTER acquisition software v2 × 90.2 (HEKA Electronic). ..

Article Title: A valve-like mechanism controls desensitization of functional mammalian isoforms of acid-sensing ion channels
Article Snippet: Psalmotoxin-1 was from Alomone Labs, Tris(2-carboxyethyl)phosphine (TCEP) and other chemicals were from Sigma-Aldrich. .. hASIC1a currents were recorded in excised patches from oocytes in the outside-out configuration using a HEKA patch clamp EPC10 amplifier and PATCHMASTER acquisition software v2 × 90.2 (HEKA Electronic). ..

other:

Article Title: A valve-like mechanism controls desensitization of functional mammalian isoforms of acid-sensing ion channels
Article Snippet: Patch clamp hASIC1a currents were recorded in excised patches from oocytes in the outside-out configuration using a HEKA patch clamp EPC10 amplifier and PATCHMASTER acquisition software v2 90.2 (HEKA Electronic).



Similar Products

90
HEKA Electronics Incorporated patchmaster software with heka epc10
Patchmaster Software With Heka Epc10, supplied by HEKA Electronics Incorporated, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/patchmaster+(heka)+software/epc+10+amplifier/us12303496-590-7-9
Average 90 stars, based on 1 article reviews
patchmaster software with heka epc10 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
HEKA Electronics Incorporated patchmaster software (heka)
Patchmaster Software (Heka), supplied by HEKA Electronics Incorporated, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/patchmaster+(heka)+software/patchmaster+software/bio_rxiv__2025__01__23__634330-113-11-7
Average 90 stars, based on 1 article reviews
patchmaster software (heka) - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

99
Danaher Inc patchmaster software heka
Patchmaster Software Heka, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/patchmaster+(heka)+software/MultiClamp+700B+current+%26+patch+clamp+amplifier/pmc11733414-109-22-33
Average 99 stars, based on 1 article reviews
patchmaster software heka - by Bioz Stars, 2026-09
99/100 stars
  Buy from Supplier

90
HEKA Electronics Incorporated heka patchmaster 2.65 software
Heka Patchmaster 2.65 Software, supplied by HEKA Electronics Incorporated, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/patchmaster+(heka)+software/heka+patchmaster/pm39566665-111-41-45
Average 90 stars, based on 1 article reviews
heka patchmaster 2.65 software - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

99
Danaher Inc patchmaster 1 2 software heka
Patchmaster 1 2 Software Heka, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/patchmaster+(heka)+software/MultiClamp+700B+current+%26+patch+clamp+amplifier/10__1134_slash_s0022093024060140-52-18-28
Average 99 stars, based on 1 article reviews
patchmaster 1 2 software heka - by Bioz Stars, 2026-09
99/100 stars
  Buy from Supplier

90
HEKA Elektronik heka patchmaster software
Reagents and tools table
Heka Patchmaster Software, supplied by HEKA Elektronik, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/patchmaster+(heka)+software/heka+patchmaster+software/pmc11148119-449-0-9
Average 90 stars, based on 1 article reviews
heka patchmaster software - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
HEKA Elektronik heka’s patchmaster software
Reagents and tools table
Heka’s Patchmaster Software, supplied by HEKA Elektronik, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/patchmaster+(heka)+software/heka+patchmaster+software/bio_rxiv__2024__01__08__574608-181-9-4
Average 90 stars, based on 1 article reviews
heka’s patchmaster software - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


Reagents and tools table

Journal: The EMBO Journal

Article Title: Functional and structural insights into activation of TRPV2 by weak acids

doi: 10.1038/s44318-024-00106-4

Figure Lengend Snippet: Reagents and tools table

Article Snippet: HEKA Patchmaster software and EPC 10 USB HEKA amplifier (HEKA Elektronik, Lamprecht, Germany) were used for patch clamp recordings.

Techniques: Recombinant, Purification, Plasmid Preparation, Sequencing, Protease Inhibitor, Transfection, Modification, Software, Transformation Assay, Mutagenesis