Review




Structured Review

Sun Nuclear Corporation arccheck helical diode array sun nuclear
Device measurement averages taken across all six patient plans. The measurement used for the reproducibility analysis is given in parentheses (percent of pixels passing gamma for the planar devices, the nC charge reading for the cc04 ion chamber, and the dose (cGy) measured for the multiple ion chamber (MIC) phantom. The averages reported are for both the “redelivery” and “total delivery” measurements (three measurements each), which over the six patients translates to averages taken over 18 measurements each for “redelivery” and “total delivery”
Arccheck Helical Diode Array Sun Nuclear, supplied by Sun Nuclear Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mapcheck2+2d+array/arccheck+helical+diode+array/pmc04048867-48-33-37
Average 90 stars, based on 1 article reviews
arccheck helical diode array sun nuclear - by Bioz Stars, 2026-11
90/100 stars

Images

1) Product Images from "Reproducibility in patient‐specific IMRT QA"

Article Title: Reproducibility in patient‐specific IMRT QA

Journal: Journal of Applied Clinical Medical Physics

doi: 10.1120/jacmp.v15i3.4741

Device measurement averages taken across all six patient plans. The measurement used for the reproducibility analysis is given in parentheses (percent of pixels passing gamma for the planar devices, the nC charge reading for the cc04 ion chamber, and the dose (cGy) measured for the multiple ion chamber (MIC) phantom. The averages reported are for both the “redelivery” and “total delivery” measurements (three measurements each), which over the six patients translates to averages taken over 18 measurements each for “redelivery” and “total delivery”
Figure Legend Snippet: Device measurement averages taken across all six patient plans. The measurement used for the reproducibility analysis is given in parentheses (percent of pixels passing gamma for the planar devices, the nC charge reading for the cc04 ion chamber, and the dose (cGy) measured for the multiple ion chamber (MIC) phantom. The averages reported are for both the “redelivery” and “total delivery” measurements (three measurements each), which over the six patients translates to averages taken over 18 measurements each for “redelivery” and “total delivery”

Techniques Used:

Venn diagram showing statistically significant grouping of dosimetric systems based on their “total delivery” reproducibility. The coefficient of variation is given in parentheses. The coefficient of variation of film was significantly different from the cc04 ion chamber, MapCHECK with AP beams formed into a composite plane, MapCHECK with AP beams analyzed in a field‐by‐field analysis, and the multiple ion chamber (MIC) phantom. The coefficient of variation of the ArcCHECK and the MapCHECK with the original rotational gantry angles were not significantly different from either group.
Figure Legend Snippet: Venn diagram showing statistically significant grouping of dosimetric systems based on their “total delivery” reproducibility. The coefficient of variation is given in parentheses. The coefficient of variation of film was significantly different from the cc04 ion chamber, MapCHECK with AP beams formed into a composite plane, MapCHECK with AP beams analyzed in a field‐by‐field analysis, and the multiple ion chamber (MIC) phantom. The coefficient of variation of the ArcCHECK and the MapCHECK with the original rotational gantry angles were not significantly different from either group.

Techniques Used:

Isolating the error caused by setup alone from the redelivery and total coefficients of variation (CV) averaged across all patient plans
Figure Legend Snippet: Isolating the error caused by setup alone from the redelivery and total coefficients of variation (CV) averaged across all patient plans

Techniques Used:

Related Articles

other:

Article Title: Prediction of dosimetric accuracy for VMAT plans using plan complexity parameters via machine learning.
Article Snippet: A cc ep te d A rt ic le This article is protected by copyright.. All rights reserved.. Purpose: The dosimetric accuracies of volumetric modulated arc therapy (VMAT) plans were predicted using plan complexity parameters via machine learning.

Article Title: Reproducibility in patient‐specific IMRT QA
Article Snippet: Four commercial dosimeters and one in‐house‐designed dosimeter were used for this study: EDR2 radiographic film (Kodak Carestream, Rochester, NY), Wellhofer cc04 ion chamber (CNMC, Nashville, TN), MapCHECK2 2D diode array (Sun Nuclear Corporation), ArcCHECK helical diode array (Sun Nuclear Corporation), and an in‐house‐designed multiple ion chamber (MIC) phantom.

Article Title: Volumetric modulated arc therapy of head-and-neck cancer on a fast-rotating O-ring linac: Plan quality and delivery time comparison with a C-arm linac.
Article Snippet: https://doi.org/10.1016/j.radonc.2018.04.021 0167-8140/ 2018 Elsevier B.V. All rights reserved.. ⇑ Corresponding authors at: University Hospitals Leuven, Department of Radiation Oncology, Herestraat 49, B-3000 Leuven, Belgium.. E-mail addresses: [email protected] (S. Michiels), tom.depuydt@ kuleuven.be (T. Depuydt).

Article Title: The impact of plan complexity on calculation and measurement-based pre-treatment verifications for sliding-window intensity-modulated radiotherapy
Article Snippet: Both helical-array ArcCHECK (Sun Nuclear Corporations, Melbourne, FL, USA) and cross-array Delta 4 phantom+ (Delta 4+ , ScandiDos, Uppsala, Sweden) were used in linac #1, and oblique cross-array Delta 4PT (ScandiDos, Uppsala, Sweden) was used in linac #2.

Comparison:

Article Title: Analysis of dose comparison techniques for patient‐specific quality assurance in radiation therapy
Article Snippet: .. This study evaluated the D&C, MADD, local and global gamma dose comparison techniques across a variety of agreement criteria and LDT, for 429 existing PSQA measurements obtained using ArcCheck helical diode array (Sun Nuclear Corporation, Melbourne, FL), including 57 beams that failed departmental quality assurance tests, for both HT and VMAT treatments. ..

Countercurrent Chromatography:

Article Title: AOCMP-SEACOMP 2024 : 10-13 October 2024, Penang, Malaysia.
Article Snippet: The Abstract Book of the 24th Asia-Oceania Congress of Medical Physics (AOCMP) and the 22ndSoutheast Asia Congress ofMedical Physics (SEACOMP) 2024 consists of 313 abstracts, encompassing a diverse range of topics including radiation oncology, diagnostic radiology, nuclear medicine, radiation protection and safety, and education and training.. The AOCMP-SEACOMP 2024 was held in Penang, Malaysia from 10 to 13 October.. The abstracts highlight innovative research and development in the fields, aligned with the congress theme ‘‘Revolutionising Patient Care Through Medical Physics’’.

Produced:

Article Title: Technical note: A modified gamma evaluation method for dose distribution comparisons
Article Snippet: .. A set of pre‐existing PSQA results, consisting of 53 arcs from 25 VMAT treatment plans measured using the ArcCheck (Sun Nuclear Corporation, Melbourne, USA) helical diode arrays, were arbitrarily selected and used to validate the performance of the code, by attempting to duplicate the gamma evaluation results produced during conventional PSQA tests using the SNC patient software (version 6.2.2) with Van Dyk global gamma analysis and 2D distance‐to‐agreement. ..

Software:

Article Title: Technical note: A modified gamma evaluation method for dose distribution comparisons
Article Snippet: .. A set of pre‐existing PSQA results, consisting of 53 arcs from 25 VMAT treatment plans measured using the ArcCheck (Sun Nuclear Corporation, Melbourne, USA) helical diode arrays, were arbitrarily selected and used to validate the performance of the code, by attempting to duplicate the gamma evaluation results produced during conventional PSQA tests using the SNC patient software (version 6.2.2) with Van Dyk global gamma analysis and 2D distance‐to‐agreement. ..



Similar Products

90
Sun Nuclear Corporation 2d diode array detector mapcheck2
2d Diode Array Detector Mapcheck2, supplied by Sun Nuclear Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mapcheck2+2d+array/mapcheck/pm37408321-89-15-20
Average 90 stars, based on 1 article reviews
2d diode array detector mapcheck2 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Sun Nuclear Corporation 2d diode detector array mapcheck2
The comparison of the <t> 2D, </t> 3D globe, and organ-specific GP (%) for 30 NPC cases with different gamma criteria
2d Diode Detector Array Mapcheck2, supplied by Sun Nuclear Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mapcheck2+2d+array/mapcheck/pmc05856312-109-9-14
Average 90 stars, based on 1 article reviews
2d diode detector array mapcheck2 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Sun Nuclear Corporation mapcheck2 2d array
The comparison of the <t> 2D, </t> 3D globe, and organ-specific GP (%) for 30 NPC cases with different gamma criteria
Mapcheck2 2d Array, supplied by Sun Nuclear Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mapcheck2+2d+array/mapcheck/pmc05840895-71-1-19
Average 90 stars, based on 1 article reviews
mapcheck2 2d array - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Sun Nuclear Corporation diode detector-based 2d diode array dosimeter mapcheck2
<t>2D</t> images of the passing rate based on gamma evaluation for various dosimetric tools. (A) Film, (B) diode array (Mapcheck), (C) ion chamber array (MatriXX), (D) Portal dosimetry.
Diode Detector Based 2d Diode Array Dosimeter Mapcheck2, supplied by Sun Nuclear Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mapcheck2+2d+array/mapcheck/pmc04577229-46-7-12
Average 90 stars, based on 1 article reviews
diode detector-based 2d diode array dosimeter mapcheck2 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Varian Medical mapcheck2 2d detector array
<t>2D</t> images of the passing rate based on gamma evaluation for various dosimetric tools. (A) Film, (B) diode array (Mapcheck), (C) ion chamber array (MatriXX), (D) Portal dosimetry.
Mapcheck2 2d Detector Array, supplied by Varian Medical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mapcheck2+2d+array/mapcheck/pmc05711119-17-1-20
Average 90 stars, based on 1 article reviews
mapcheck2 2d detector array - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Sun Nuclear Corporation mapcheck2 2d diode array sun nuclear
<t>2D</t> images of the passing rate based on gamma evaluation for various dosimetric tools. (A) Film, (B) diode array (Mapcheck), (C) ion chamber array (MatriXX), (D) Portal dosimetry.
Mapcheck2 2d Diode Array Sun Nuclear, supplied by Sun Nuclear Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mapcheck2+2d+array/mapcheck/pmc04048867-48-26-30
Average 90 stars, based on 1 article reviews
mapcheck2 2d diode array sun nuclear - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


The comparison of the  2D,  3D globe, and organ-specific GP (%) for 30 NPC cases with different gamma criteria

Journal: Radiation Oncology (London, England)

Article Title: Retrospective dosimetry study of intensity-modulated radiation therapy for nasopharyngeal carcinoma: measurement-guided dose reconstruction and analysis

doi: 10.1186/s13014-018-0993-2

Figure Lengend Snippet: The comparison of the 2D, 3D globe, and organ-specific GP (%) for 30 NPC cases with different gamma criteria

Article Snippet: All the 30 IMRT plans were validated with a 2D diode detector array (Mapcheck2, Sun Nuclear Corporation, Melbourne, FL).

Techniques: Comparison

Pearson correlation coefficient with three type gamma pass rate and D V , V D

Journal: Radiation Oncology (London, England)

Article Title: Retrospective dosimetry study of intensity-modulated radiation therapy for nasopharyngeal carcinoma: measurement-guided dose reconstruction and analysis

doi: 10.1186/s13014-018-0993-2

Figure Lengend Snippet: Pearson correlation coefficient with three type gamma pass rate and D V , V D

Article Snippet: All the 30 IMRT plans were validated with a 2D diode detector array (Mapcheck2, Sun Nuclear Corporation, Melbourne, FL).

Techniques:

2D images of the passing rate based on gamma evaluation for various dosimetric tools. (A) Film, (B) diode array (Mapcheck), (C) ion chamber array (MatriXX), (D) Portal dosimetry.

Journal: Radiology and Oncology

Article Title: A comparison of the quality assurance of four dosimetric tools for intensity modulated radiation therapy

doi: 10.1515/raon-2015-0021

Figure Lengend Snippet: 2D images of the passing rate based on gamma evaluation for various dosimetric tools. (A) Film, (B) diode array (Mapcheck), (C) ion chamber array (MatriXX), (D) Portal dosimetry.

Article Snippet: Among these tools are a diode detector-based 2D diode array dosimeter (MapCheck2; Sun Nuclear Corporation, Melbourne, Florida), a 2D ion chamber array dosimeter (I’mRT MatriXX; IBA) and portal dosimetry using an electronic portal imaging device (EPID).

Techniques: