Review




Structured Review

Arthrex Inc suturelasso sd wire loop
Intraoperative photographs detailing minimally invasive arthroscopic treatment of isolated Rockwood type III acute acromioclavicular dislocation in left shoulder of male patient via Dog Bone Button. The arthroscopic steps are as follows: (A) Through the anterolateral portal, the inferior surface of the coracoid is visualized. By use of the Serfas vaporizer instrument introduced through the anteroinferior portal, the inferior surface is skeletonized, exposing it as much as possible. (B) Visualization of inferior surface of coracoid from anteroinferior portal. (C) Visualization of inferior surface of coracoid from anteroinferior portal, followed by skeletonization of inferior surface using Serfas vaporizer instrument through anterolateral portal. (D) Visualization of inferior surface of coracoid from anteroinferior portal, with skeletonization of inferior surface using 4.0-mm powered shaver (Stryker) through anterolateral portal. (E) Palpation of medial margin of coracoid with probe (Stryker) introduced through anterolateral portal, with visualization from anteroinferior portal. (F) Palpation of medial margin of coracoid using the extremity of acromion Arthrex compass at 90° angle through anterolateral portal, with visualization from anteroinferior portal. (G) Visualization of drill insertion from anteroinferior portal, performed with Arthrex compass and drill, both introduced through anterolateral portal. (H) Passage of <t>SutureLasso</t> SD Wire Loop through Arthrex cannulated drill, visualized from anterolateral portal. (I) Retrieval of SutureLasso SD Wire Loop from Arthrex cannulated drill, correctly positioned at inferior surface of coracoid base. This is visualized from the anterolateral portal, and retrieval is performed with an arthroscopic grasper (Stryker) through the anteroinferior portal. (J) After loading the 2 FiberTape sutures of the Dog Bone Button onto the SutureLasso, the SutureLasso is retrieved, thereby pulling the 2 FiberTape sutures of the Dog Bone Button through the coracoid. This step is visualized from the anterolateral portal, with the FiberTape sutures being inserted through the anteroinferior portal. (K) Visualization of Dog Bone Button in vertical position on inferior surface of coracoid from anterolateral portal. (L) Visualization of Dog Bone Button properly positioned at inferior surface of coracoid base from anterolateral portal.
Suturelasso Sd Wire Loop, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/loop+wire/suturelasso+wire+loop/pmc12255453-58-9-13
Average 90 stars, based on 1 article reviews
suturelasso sd wire loop - by Bioz Stars, 2026-11
90/100 stars

Images

1) Product Images from "Two Scope Portals in Simple Acromioclavicular Joint Type III Injury"

Article Title: Two Scope Portals in Simple Acromioclavicular Joint Type III Injury

Journal: Arthroscopy Techniques

doi: 10.1016/j.eats.2025.103536

Intraoperative photographs detailing minimally invasive arthroscopic treatment of isolated Rockwood type III acute acromioclavicular dislocation in left shoulder of male patient via Dog Bone Button. The arthroscopic steps are as follows: (A) Through the anterolateral portal, the inferior surface of the coracoid is visualized. By use of the Serfas vaporizer instrument introduced through the anteroinferior portal, the inferior surface is skeletonized, exposing it as much as possible. (B) Visualization of inferior surface of coracoid from anteroinferior portal. (C) Visualization of inferior surface of coracoid from anteroinferior portal, followed by skeletonization of inferior surface using Serfas vaporizer instrument through anterolateral portal. (D) Visualization of inferior surface of coracoid from anteroinferior portal, with skeletonization of inferior surface using 4.0-mm powered shaver (Stryker) through anterolateral portal. (E) Palpation of medial margin of coracoid with probe (Stryker) introduced through anterolateral portal, with visualization from anteroinferior portal. (F) Palpation of medial margin of coracoid using the extremity of acromion Arthrex compass at 90° angle through anterolateral portal, with visualization from anteroinferior portal. (G) Visualization of drill insertion from anteroinferior portal, performed with Arthrex compass and drill, both introduced through anterolateral portal. (H) Passage of SutureLasso SD Wire Loop through Arthrex cannulated drill, visualized from anterolateral portal. (I) Retrieval of SutureLasso SD Wire Loop from Arthrex cannulated drill, correctly positioned at inferior surface of coracoid base. This is visualized from the anterolateral portal, and retrieval is performed with an arthroscopic grasper (Stryker) through the anteroinferior portal. (J) After loading the 2 FiberTape sutures of the Dog Bone Button onto the SutureLasso, the SutureLasso is retrieved, thereby pulling the 2 FiberTape sutures of the Dog Bone Button through the coracoid. This step is visualized from the anterolateral portal, with the FiberTape sutures being inserted through the anteroinferior portal. (K) Visualization of Dog Bone Button in vertical position on inferior surface of coracoid from anterolateral portal. (L) Visualization of Dog Bone Button properly positioned at inferior surface of coracoid base from anterolateral portal.
Figure Legend Snippet: Intraoperative photographs detailing minimally invasive arthroscopic treatment of isolated Rockwood type III acute acromioclavicular dislocation in left shoulder of male patient via Dog Bone Button. The arthroscopic steps are as follows: (A) Through the anterolateral portal, the inferior surface of the coracoid is visualized. By use of the Serfas vaporizer instrument introduced through the anteroinferior portal, the inferior surface is skeletonized, exposing it as much as possible. (B) Visualization of inferior surface of coracoid from anteroinferior portal. (C) Visualization of inferior surface of coracoid from anteroinferior portal, followed by skeletonization of inferior surface using Serfas vaporizer instrument through anterolateral portal. (D) Visualization of inferior surface of coracoid from anteroinferior portal, with skeletonization of inferior surface using 4.0-mm powered shaver (Stryker) through anterolateral portal. (E) Palpation of medial margin of coracoid with probe (Stryker) introduced through anterolateral portal, with visualization from anteroinferior portal. (F) Palpation of medial margin of coracoid using the extremity of acromion Arthrex compass at 90° angle through anterolateral portal, with visualization from anteroinferior portal. (G) Visualization of drill insertion from anteroinferior portal, performed with Arthrex compass and drill, both introduced through anterolateral portal. (H) Passage of SutureLasso SD Wire Loop through Arthrex cannulated drill, visualized from anterolateral portal. (I) Retrieval of SutureLasso SD Wire Loop from Arthrex cannulated drill, correctly positioned at inferior surface of coracoid base. This is visualized from the anterolateral portal, and retrieval is performed with an arthroscopic grasper (Stryker) through the anteroinferior portal. (J) After loading the 2 FiberTape sutures of the Dog Bone Button onto the SutureLasso, the SutureLasso is retrieved, thereby pulling the 2 FiberTape sutures of the Dog Bone Button through the coracoid. This step is visualized from the anterolateral portal, with the FiberTape sutures being inserted through the anteroinferior portal. (K) Visualization of Dog Bone Button in vertical position on inferior surface of coracoid from anterolateral portal. (L) Visualization of Dog Bone Button properly positioned at inferior surface of coracoid base from anterolateral portal.

Techniques Used: Isolation

Related Articles

Isolation:

Article Title: Osteosynthesis of a patellar fracture with repair of the knee extensor mechanism: Case report
Article Snippet: Reduction and osteosynthesis of the patella with two 3.5 mm cannulated screws (DePuy-Synthes, Warsaw, Indiana, ) is performed 13 days after admission and cerclage with a 0.8 mm wire loop, two 5.0 mm anchors (Arthrex, Inc. Naples, Florida, USA) are fixed to the distal patella, a Krackow suture is made distally, two 6.5 mm anchors (Arthrex, Inc. Naples, Florida, USA) are positioned under the anterior tuberosity of the tibia, a Krackow suture is made proximal , a reduction is visualized under fluoroscopic vision ( ).

Article Title: All-Arthroscopic Coracoacromial Ligament Transfer: The Modified Neviaser Procedure for Acromioclavicular Dislocations
Article Snippet: Insert a SutureLasso Wire-Loop (Arthrex) through the drill bit and retrieve it via the anteroinferior portal ( A).

Article Title: Suture-button suspensionplasty for the treatment of thumb carpometacarpal joint arthritis.
Article Snippet: Trapeziectomy alone has regained popularity for the treatment of thumb carpometacarpal joint arthritis, and the literature supports its use for this common problem.. Suture button suspensionplasty eliminates the need for troublesome Kirschner wire fixation following trapeziectomy.. Suture button suspensionplasty requires no soft tissue healing and therefore rehabilitation following this procedure may be begun as early as one week following surgery, thereby accelerating recovery.

Article Title: The Effect of Early Range of Motion on Quality of Life, Clinical Outcome, and Repair Integrity After Arthroscopic Rotator Cuff Repair.
Article Snippet: Purpose: To compare the effect of early versus delayed motion protocols on quality of life, clinical outcomes, and repair integrity in patients who have undergone arthroscopic single-tendon rotator cuff repair.. Methods: This was a prospective, randomized, investigator-blinded clinical trial.. Seventy-three patients from a single surgeon’s practice who underwent arthroscopic repair of a single-tendon rotator cuff tear were randomized to either an early motion protocol (starting 2 to 3 days after surgery) or a delayed motion protocol (starting 28 days after surgery).

Article Title: Two Scope Portals in Simple Acromioclavicular Joint Type III Injury
Article Snippet: The trocar is removed from the drill, and a SutureLasso SD Wire Loop (Arthrex) is passed through the drill cannulation loop and then retrieved through the anteroinferior portal, viewing through the anterolateral portal.

Article Title: All-Arthroscopic Coracoacromial Ligament Transfer: The Modified Neviaser Procedure for Acromioclavicular Dislocations
Article Snippet: Using a SutureLasso Wire-Loop (Arthrex), take the strand from the posterior bundle of the CA ligament through the drilled hole ( D).

Article Title: A Novel Surgical Technique for Fixation of Recurrent Acromioclavicular Dislocations: AC Dog Bone Technique in Combination with Autogenous Semitendinosus Tendon Graft
Article Snippet: SutureLasso Wire Loops (Arthrex, Inc., Naples, Florida) were passed through the drill holes.



Similar Products

86
Arthrex Inc nitinol wire loop
Nitinol Wire Loop, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/loop+wire/nitinol+wire/pm41324432-58-8-11
Average 86 stars, based on 1 article reviews
nitinol wire loop - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Arthrex Inc wire loop tool
Wire Loop Tool, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/loop+wire/loop+tool+wire/pm41067624-68-14-17
Average 86 stars, based on 1 article reviews
wire loop tool - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Instech Laboratories loop wire
Loop Wire, supplied by Instech Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/loop+wire/loop+wire/pmc12448133-258-12-17
Average 86 stars, based on 1 article reviews
loop wire - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

90
Arthrex Inc wire loop arthrex
Wire Loop Arthrex, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/loop+wire/fiberloops+arthrex/pmc12277742-66-1-3
Average 90 stars, based on 1 article reviews
wire loop arthrex - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

86
Agilis Biotherapeutics wire loop
Wire Loop, supplied by Agilis Biotherapeutics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/loop+wire/exchange+length/pmc12441537-73-1-12
Average 86 stars, based on 1 article reviews
wire loop - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Merck & Co conventional wire loop
Conventional Wire Loop, supplied by Merck & Co, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/loop+wire/conventional+loop+wire/pmc12486511-77-27-30
Average 86 stars, based on 1 article reviews
conventional wire loop - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

90
Arthrex Inc suturelasso sd wire loop
Intraoperative photographs detailing minimally invasive arthroscopic treatment of isolated Rockwood type III acute acromioclavicular dislocation in left shoulder of male patient via Dog Bone Button. The arthroscopic steps are as follows: (A) Through the anterolateral portal, the inferior surface of the coracoid is visualized. By use of the Serfas vaporizer instrument introduced through the anteroinferior portal, the inferior surface is skeletonized, exposing it as much as possible. (B) Visualization of inferior surface of coracoid from anteroinferior portal. (C) Visualization of inferior surface of coracoid from anteroinferior portal, followed by skeletonization of inferior surface using Serfas vaporizer instrument through anterolateral portal. (D) Visualization of inferior surface of coracoid from anteroinferior portal, with skeletonization of inferior surface using 4.0-mm powered shaver (Stryker) through anterolateral portal. (E) Palpation of medial margin of coracoid with probe (Stryker) introduced through anterolateral portal, with visualization from anteroinferior portal. (F) Palpation of medial margin of coracoid using the extremity of acromion Arthrex compass at 90° angle through anterolateral portal, with visualization from anteroinferior portal. (G) Visualization of drill insertion from anteroinferior portal, performed with Arthrex compass and drill, both introduced through anterolateral portal. (H) Passage of <t>SutureLasso</t> SD Wire Loop through Arthrex cannulated drill, visualized from anterolateral portal. (I) Retrieval of SutureLasso SD Wire Loop from Arthrex cannulated drill, correctly positioned at inferior surface of coracoid base. This is visualized from the anterolateral portal, and retrieval is performed with an arthroscopic grasper (Stryker) through the anteroinferior portal. (J) After loading the 2 FiberTape sutures of the Dog Bone Button onto the SutureLasso, the SutureLasso is retrieved, thereby pulling the 2 FiberTape sutures of the Dog Bone Button through the coracoid. This step is visualized from the anterolateral portal, with the FiberTape sutures being inserted through the anteroinferior portal. (K) Visualization of Dog Bone Button in vertical position on inferior surface of coracoid from anterolateral portal. (L) Visualization of Dog Bone Button properly positioned at inferior surface of coracoid base from anterolateral portal.
Suturelasso Sd Wire Loop, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/loop+wire/suturelasso+wire+loop/pmc12255453-58-9-13
Average 90 stars, based on 1 article reviews
suturelasso sd wire loop - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Arthrex Inc nitinol wire shuttle loop
<t>Shuttle</t> <t>loop</t> preparation and graft passage for reduction. (A) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. A <t>nitinol</t> <t>wire</t> shuttle loop with a passing hook (Arthrex) is cautiously placed close to the medial cortex of the coracoid base to avoid nerve injury. (B) Outside view of left shoulder with patient in beach-chair position. A FiberTape (white arrow) along with the long head of the biceps tendon (LHBT) graft (black arrow), in a venae comitantes fashion, is dragged into the subacromial space. The green arrows indicate the shuttle loop, and the yellow arrows indicate the epidural needles. (C) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape with 1 tail suture (“string”) of LHBT under base of coracoid. (D) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape along with LHBT around base of coracoid using shuttle loop. (E) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The grafts loop around the coracoid base. (F) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The 2 ends of the grafts are crossed and form an X shape within the coracoclavicular interval. The stars indicate the coracoid base.
Nitinol Wire Shuttle Loop, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/loop+wire/nitinol+wire/pmc12255420-56-4-25
Average 90 stars, based on 1 article reviews
nitinol wire shuttle loop - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Intraoperative photographs detailing minimally invasive arthroscopic treatment of isolated Rockwood type III acute acromioclavicular dislocation in left shoulder of male patient via Dog Bone Button. The arthroscopic steps are as follows: (A) Through the anterolateral portal, the inferior surface of the coracoid is visualized. By use of the Serfas vaporizer instrument introduced through the anteroinferior portal, the inferior surface is skeletonized, exposing it as much as possible. (B) Visualization of inferior surface of coracoid from anteroinferior portal. (C) Visualization of inferior surface of coracoid from anteroinferior portal, followed by skeletonization of inferior surface using Serfas vaporizer instrument through anterolateral portal. (D) Visualization of inferior surface of coracoid from anteroinferior portal, with skeletonization of inferior surface using 4.0-mm powered shaver (Stryker) through anterolateral portal. (E) Palpation of medial margin of coracoid with probe (Stryker) introduced through anterolateral portal, with visualization from anteroinferior portal. (F) Palpation of medial margin of coracoid using the extremity of acromion Arthrex compass at 90° angle through anterolateral portal, with visualization from anteroinferior portal. (G) Visualization of drill insertion from anteroinferior portal, performed with Arthrex compass and drill, both introduced through anterolateral portal. (H) Passage of SutureLasso SD Wire Loop through Arthrex cannulated drill, visualized from anterolateral portal. (I) Retrieval of SutureLasso SD Wire Loop from Arthrex cannulated drill, correctly positioned at inferior surface of coracoid base. This is visualized from the anterolateral portal, and retrieval is performed with an arthroscopic grasper (Stryker) through the anteroinferior portal. (J) After loading the 2 FiberTape sutures of the Dog Bone Button onto the SutureLasso, the SutureLasso is retrieved, thereby pulling the 2 FiberTape sutures of the Dog Bone Button through the coracoid. This step is visualized from the anterolateral portal, with the FiberTape sutures being inserted through the anteroinferior portal. (K) Visualization of Dog Bone Button in vertical position on inferior surface of coracoid from anterolateral portal. (L) Visualization of Dog Bone Button properly positioned at inferior surface of coracoid base from anterolateral portal.

Journal: Arthroscopy Techniques

Article Title: Two Scope Portals in Simple Acromioclavicular Joint Type III Injury

doi: 10.1016/j.eats.2025.103536

Figure Lengend Snippet: Intraoperative photographs detailing minimally invasive arthroscopic treatment of isolated Rockwood type III acute acromioclavicular dislocation in left shoulder of male patient via Dog Bone Button. The arthroscopic steps are as follows: (A) Through the anterolateral portal, the inferior surface of the coracoid is visualized. By use of the Serfas vaporizer instrument introduced through the anteroinferior portal, the inferior surface is skeletonized, exposing it as much as possible. (B) Visualization of inferior surface of coracoid from anteroinferior portal. (C) Visualization of inferior surface of coracoid from anteroinferior portal, followed by skeletonization of inferior surface using Serfas vaporizer instrument through anterolateral portal. (D) Visualization of inferior surface of coracoid from anteroinferior portal, with skeletonization of inferior surface using 4.0-mm powered shaver (Stryker) through anterolateral portal. (E) Palpation of medial margin of coracoid with probe (Stryker) introduced through anterolateral portal, with visualization from anteroinferior portal. (F) Palpation of medial margin of coracoid using the extremity of acromion Arthrex compass at 90° angle through anterolateral portal, with visualization from anteroinferior portal. (G) Visualization of drill insertion from anteroinferior portal, performed with Arthrex compass and drill, both introduced through anterolateral portal. (H) Passage of SutureLasso SD Wire Loop through Arthrex cannulated drill, visualized from anterolateral portal. (I) Retrieval of SutureLasso SD Wire Loop from Arthrex cannulated drill, correctly positioned at inferior surface of coracoid base. This is visualized from the anterolateral portal, and retrieval is performed with an arthroscopic grasper (Stryker) through the anteroinferior portal. (J) After loading the 2 FiberTape sutures of the Dog Bone Button onto the SutureLasso, the SutureLasso is retrieved, thereby pulling the 2 FiberTape sutures of the Dog Bone Button through the coracoid. This step is visualized from the anterolateral portal, with the FiberTape sutures being inserted through the anteroinferior portal. (K) Visualization of Dog Bone Button in vertical position on inferior surface of coracoid from anterolateral portal. (L) Visualization of Dog Bone Button properly positioned at inferior surface of coracoid base from anterolateral portal.

Article Snippet: The trocar is removed from the drill, and a SutureLasso SD Wire Loop (Arthrex) is passed through the drill cannulation loop and then retrieved through the anteroinferior portal, viewing through the anterolateral portal.

Techniques: Isolation

Shuttle loop preparation and graft passage for reduction. (A) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. A nitinol wire shuttle loop with a passing hook (Arthrex) is cautiously placed close to the medial cortex of the coracoid base to avoid nerve injury. (B) Outside view of left shoulder with patient in beach-chair position. A FiberTape (white arrow) along with the long head of the biceps tendon (LHBT) graft (black arrow), in a venae comitantes fashion, is dragged into the subacromial space. The green arrows indicate the shuttle loop, and the yellow arrows indicate the epidural needles. (C) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape with 1 tail suture (“string”) of LHBT under base of coracoid. (D) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape along with LHBT around base of coracoid using shuttle loop. (E) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The grafts loop around the coracoid base. (F) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The 2 ends of the grafts are crossed and form an X shape within the coracoclavicular interval. The stars indicate the coracoid base.

Journal: Arthroscopy Techniques

Article Title: Autologous Long Head of Biceps Tendon With High-Strength Suture for Reconstruction of Coracoclavicular Ligament

doi: 10.1016/j.eats.2025.103465

Figure Lengend Snippet: Shuttle loop preparation and graft passage for reduction. (A) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. A nitinol wire shuttle loop with a passing hook (Arthrex) is cautiously placed close to the medial cortex of the coracoid base to avoid nerve injury. (B) Outside view of left shoulder with patient in beach-chair position. A FiberTape (white arrow) along with the long head of the biceps tendon (LHBT) graft (black arrow), in a venae comitantes fashion, is dragged into the subacromial space. The green arrows indicate the shuttle loop, and the yellow arrows indicate the epidural needles. (C) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape with 1 tail suture (“string”) of LHBT under base of coracoid. (D) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape along with LHBT around base of coracoid using shuttle loop. (E) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The grafts loop around the coracoid base. (F) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The 2 ends of the grafts are crossed and form an X shape within the coracoclavicular interval. The stars indicate the coracoid base.

Article Snippet: Under arthroscopic visualization, a nitinol wire shuttle loop is passed around the base of the coracoid from medial to lateral with a passing hook (AR-7806; Arthrex), which is cautiously placed close to the medial cortex of the coracoid base to avoid nerve injury ( A).

Techniques: