Review



labspec 5 raman spectroscopy software  (HORIBA Ltd)


Bioz Verified Symbol HORIBA Ltd is a verified supplier
Bioz Manufacturer Symbol HORIBA Ltd manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 94

    Structured Review

    HORIBA Ltd labspec 5 raman spectroscopy software
    Fig. 6 | Estimating the far-field spatial resolution of a TERS system via <t>Raman</t> imaging of an SWCNT. a, Confocal Raman image generated from the 1,591-cm−1 band of an isolated SWCNT. Pixel size: 20 nm; integration time: 1 s. Scale bar, 100 nm. b, Intensity profile along the line marked in a fitted with a Gaussian curve (red line) after linear background subtraction, which is close to the Abbe’s diffraction-limited spatial resolution of 178.5 nm of our Raman microscope, calculated using Eq. (1). SWCNT, single-wall carbon nanotube.
    Labspec 5 Raman Spectroscopy Software, supplied by HORIBA Ltd, used in various techniques. Bioz Stars score: 94/100, based on 60 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/linear+function+in+labspec+5/Spectroscopy+Software/pm30911174-137-8-13
    Average 94 stars, based on 60 article reviews
    labspec 5 raman spectroscopy software - by Bioz Stars, 2026-11
    94/100 stars

    Images

    1) Product Images from "Nanoscale chemical imaging using tip-enhanced Raman spectroscopy."

    Article Title: Nanoscale chemical imaging using tip-enhanced Raman spectroscopy.

    Journal: Nature protocols

    doi: 10.1038/s41596-019-0132-z

    Fig. 6 | Estimating the far-field spatial resolution of a TERS system via Raman imaging of an SWCNT. a, Confocal Raman image generated from the 1,591-cm−1 band of an isolated SWCNT. Pixel size: 20 nm; integration time: 1 s. Scale bar, 100 nm. b, Intensity profile along the line marked in a fitted with a Gaussian curve (red line) after linear background subtraction, which is close to the Abbe’s diffraction-limited spatial resolution of 178.5 nm of our Raman microscope, calculated using Eq. (1). SWCNT, single-wall carbon nanotube.
    Figure Legend Snippet: Fig. 6 | Estimating the far-field spatial resolution of a TERS system via Raman imaging of an SWCNT. a, Confocal Raman image generated from the 1,591-cm−1 band of an isolated SWCNT. Pixel size: 20 nm; integration time: 1 s. Scale bar, 100 nm. b, Intensity profile along the line marked in a fitted with a Gaussian curve (red line) after linear background subtraction, which is close to the Abbe’s diffraction-limited spatial resolution of 178.5 nm of our Raman microscope, calculated using Eq. (1). SWCNT, single-wall carbon nanotube.

    Techniques Used: Imaging, Generated, Isolation, Microscopy

    Fig. 7 | Assessing the sensitivity of a TERS probe via near-field hotspot imaging. a, Raman intensity image around a TERS probe apex in contact with a PEDOT:PSS thin film sample. The image was generated from the total intensity in the 1,230–1,720-cm−1 region of the PEDOT Raman spectra. Pixel size: 20 nm; integration time: 1 s. Scale bar, 100 nm. b, Raman spectra measured at the location of highest signal intensity in a (red) and 1 µm away from it (blue). Integration time: 30 s. In this case, the intensity of the 1,454-cm−1 PEDOT Raman band has a contrast of 1.2 at the center of the TERS hotspot.
    Figure Legend Snippet: Fig. 7 | Assessing the sensitivity of a TERS probe via near-field hotspot imaging. a, Raman intensity image around a TERS probe apex in contact with a PEDOT:PSS thin film sample. The image was generated from the total intensity in the 1,230–1,720-cm−1 region of the PEDOT Raman spectra. Pixel size: 20 nm; integration time: 1 s. Scale bar, 100 nm. b, Raman spectra measured at the location of highest signal intensity in a (red) and 1 µm away from it (blue). Integration time: 30 s. In this case, the intensity of the 1,454-cm−1 PEDOT Raman band has a contrast of 1.2 at the center of the TERS hotspot.

    Techniques Used: Imaging, Generated

    Fig. 8 | Estimating the spatial resolution of a TERS image. a, TERS image of a SWCNT in air, obtained using the 1,591-cm−1 Raman band intensity. Scale bar: 50 nm. Integration time for TERS imaging: 1 s; pixel size: 10 nm; laser power at the sample: 170 µW. b, Intensity profile along the line marked in a with Gaussian curve fits to the near-field (green) and far-field (red) contributions. Spatial resolution of the TERS image is estimated from the FWHM of the green Gaussian curve to be 26 nm. FWHM, full-width at half maximum. Adapted with permission from Kumar et al.29, Royal Society of Chemistry.
    Figure Legend Snippet: Fig. 8 | Estimating the spatial resolution of a TERS image. a, TERS image of a SWCNT in air, obtained using the 1,591-cm−1 Raman band intensity. Scale bar: 50 nm. Integration time for TERS imaging: 1 s; pixel size: 10 nm; laser power at the sample: 170 µW. b, Intensity profile along the line marked in a with Gaussian curve fits to the near-field (green) and far-field (red) contributions. Spatial resolution of the TERS image is estimated from the FWHM of the green Gaussian curve to be 26 nm. FWHM, full-width at half maximum. Adapted with permission from Kumar et al.29, Royal Society of Chemistry.

    Techniques Used: Imaging

    Related Articles

    Analysis:

    Article Title: Combining laser-textured dimples and AlCrN coating to reduce wear on AISI M2 steel
    Article Snippet: .. GDOES depth profile analysis of the coatings was completed using a HORIBA GD-Profiler operating at radio frequency discharge pressure of 650 Pa and a power of 35 W. Quantified profiles were obtained automatically using the standard HORIBA QUANTUM Intelligent Quantification (IQ) software. .. The surface and cross-sectional morphology of the samples were analysed using a HITACHI scanning electron microscope (SEM).

    Software:

    Article Title: Combining laser-textured dimples and AlCrN coating to reduce wear on AISI M2 steel
    Article Snippet: .. GDOES depth profile analysis of the coatings was completed using a HORIBA GD-Profiler operating at radio frequency discharge pressure of 650 Pa and a power of 35 W. Quantified profiles were obtained automatically using the standard HORIBA QUANTUM Intelligent Quantification (IQ) software. .. The surface and cross-sectional morphology of the samples were analysed using a HITACHI scanning electron microscope (SEM).

    Article Title: Effect of dimethyl sulfoxide on universal adhesives resin bonding to caries-affected dentine
    Article Snippet: .. Post-processing was performed using Opus Spectroscopy Software (version 6.5, HORIBA Scientific; Piscataway, NJ, USA). ..

    Article Title: Surface-Controlled Photo-Fenton Activity of Cu-Fe Bimetallic Catalysts: Dual Function of Iron on Silica and Alumina Supports
    Article Snippet: For the TCSPC measurements, a picosecond photon detector (Horiba, model PPD 850) was used instead of the PMT detector. .. A Ludox SM-30 solution of colloidal silica was used as a reference to determine the instrument response function (IRF), which was used to calculate the lifetimes of the charge carriers with the FelixFL spectroscopy software (Horiba, version 1.0.48.0). ..

    Article Title: Reconstructing Quantum Dot Surfaces via Dual‐Functional Ligand Pairing Enables Efficient Shortwave Infrared Optoelectronics
    Article Snippet: .. The decay curves were nalyzed using FelixFL spectroscopy software (HORIBA) and itted with a single-exponential model. .. The organic content was easured using an organic elemental analyzer (FLASH EA1112, hermo Fisher Scientific).

    Article Title: Collective interactions along recombinase-bound D-loops could speed repair of double-strand breaks by destabilizing flanking homoduplex tails
    Article Snippet: .. Using FluorEssence spectroscopy software and the automated FluoroMax spectrofluorometer (Horiba, Edison, NJ), the emission of the fluorescein label was read using a 493 nm excitation wavelength and a 2 nm slit. ..

    Article Title: Charge Transfer States in Donor–Acceptor Bulk‐Heterojunctions as Triplet–Triplet Annihilation Sensitizer for Solid‐State Photon Upconversion
    Article Snippet: .. Mono-exponential growth and decay functions were fitted to extract upconverted photoluminescence lifetimes from the resulting decay curves using commercially available software (EzTime, HORIBA): IUC(t) ∝ e−t∕τd − e −t∕τg . .. Transient Absorption Spectroscopy: Femtosecond transient absorption (fs-TA) measurements were undertaken using an amplified laser system (Spitfire ACE, Spectra-Physics) as the excitation source, based on an 800 nm Ti:Sapphire seed (MaiTai, Spectra-Physics) and 532 nm DPSS Nd:YLF pump laser (Ascend 60, Spectra-Physics), delivering ≈150 fs 800 nm laser pulses at a 1 kHz repetition rate.

    Article Title: Composition-Dependent SERS Responses of Structurally Related Dyes on Inkjet-Printed Paper Substrates with Gold and Silver Triangular Nanoprisms
    Article Snippet: .. All Raman and SERS spectra were background-subtracted using the instrument software (HORIBA), applying a sixth-order polynomial baseline correction. ..

    Article Title: Does Localized Irradiance of Poly-wave LED Influence the Bonding Performance of Universal Adhesives to Dentin?
    Article Snippet: .. Post-processing was performed in Opus Spectroscopy Software (version 6.5, HORIBA Scientific; Piscataway, NJ, USA). ..

    Spectroscopy:

    Article Title: Effect of dimethyl sulfoxide on universal adhesives resin bonding to caries-affected dentine
    Article Snippet: .. Post-processing was performed using Opus Spectroscopy Software (version 6.5, HORIBA Scientific; Piscataway, NJ, USA). ..

    Article Title: Surface-Controlled Photo-Fenton Activity of Cu-Fe Bimetallic Catalysts: Dual Function of Iron on Silica and Alumina Supports
    Article Snippet: For the TCSPC measurements, a picosecond photon detector (Horiba, model PPD 850) was used instead of the PMT detector. .. A Ludox SM-30 solution of colloidal silica was used as a reference to determine the instrument response function (IRF), which was used to calculate the lifetimes of the charge carriers with the FelixFL spectroscopy software (Horiba, version 1.0.48.0). ..

    Article Title: Reconstructing Quantum Dot Surfaces via Dual‐Functional Ligand Pairing Enables Efficient Shortwave Infrared Optoelectronics
    Article Snippet: .. The decay curves were nalyzed using FelixFL spectroscopy software (HORIBA) and itted with a single-exponential model. .. The organic content was easured using an organic elemental analyzer (FLASH EA1112, hermo Fisher Scientific).

    Article Title: Collective interactions along recombinase-bound D-loops could speed repair of double-strand breaks by destabilizing flanking homoduplex tails
    Article Snippet: .. Using FluorEssence spectroscopy software and the automated FluoroMax spectrofluorometer (Horiba, Edison, NJ), the emission of the fluorescein label was read using a 493 nm excitation wavelength and a 2 nm slit. ..

    Article Title: Does Localized Irradiance of Poly-wave LED Influence the Bonding Performance of Universal Adhesives to Dentin?
    Article Snippet: .. Post-processing was performed in Opus Spectroscopy Software (version 6.5, HORIBA Scientific; Piscataway, NJ, USA). ..

    Automated:

    Article Title: Collective interactions along recombinase-bound D-loops could speed repair of double-strand breaks by destabilizing flanking homoduplex tails
    Article Snippet: .. Using FluorEssence spectroscopy software and the automated FluoroMax spectrofluorometer (Horiba, Edison, NJ), the emission of the fluorescein label was read using a 493 nm excitation wavelength and a 2 nm slit. ..



    Similar Products

    90
    HORIBA Ltd linear function in labspec 5
    Linear Function In Labspec 5, supplied by HORIBA Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/linear+function+in+labspec+5/linear+function+in+labspec+5/pmc06782074-90-17-19
    Average 90 stars, based on 1 article reviews
    linear function in labspec 5 - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results