Review



small-angle scattering (sas) data  (SAS institute)


Bioz Verified Symbol SAS institute is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    SAS institute small-angle scattering (sas) data
    Small Angle Scattering (Sas) Data, supplied by SAS institute, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/data+processing+software+idps/small+angle+scattering/pmc08154249-19-18-26
    Average 90 stars, based on 1 article reviews
    small-angle scattering (sas) data - by Bioz Stars, 2026-11
    90/100 stars

    Images

    Related Articles

    Nuclear Magnetic Resonance:

    Article Title: Recent Progress of Artificial Intelligence Application in Polymer Materials
    Article Snippet: Their applications involve the composition optimization [ ], experiment cost deduction [ ], properties prediction (including Young’s modulus [ ], melting temperature [ , ], thermal stability, and thermal conductivity [ , ]), and characterization analysis (such as powder diffraction (PD), pair distribution function (PDF), small-angle scattering (SAS), inelastic neutron scattering (INS), and X-ray absorption spectroscopy (XAS) [ , ]).

    Article Title: Fast calculation of small-angle scattering profiles of dense protein solutions modeled at the all-atom level
    Article Snippet: Small-angle scattering (SAS) is a uniquely powerful technique for probing the internal structures of proteins and interprotein interactions.

    Article Title: Solution conformational differences between conventional and CENP-A nucleosomes are accentuated by reversible deformation under high pressure.
    Article Snippet: Since the 1970 s, small-angle scattering (SAS) has served as an invaluable complementary tool for structural biology that has bridged the gap between atomic-level structure and solution behavior (Mohammed et al. 2024; Weiss 2017).

    Article Title: Reconfigurable Soft Actuators Constructed via Layer‐by‐layer Assembly
    Article Snippet: To study the structural basis of the stimuli-sensitivity of the two films, small-angle scattering (SAS) experiments are performed, including small-angle X-ray scattering (SAXS) and small-angle neutron scattering (SANS) (Figure S2, Supporting Information).

    Article Title: 15th EBSA congress, June 30 - July 4, 2025, Rome, Italy - Abstracts.
    Article Snippet: European Biophysics Journal (2025) 54 (Suppl 1):S1–S273 https://doi.org/10.1007/s00249-025-01757-9 15th EBSA congress June 30 – July 4, 2025, Rome, Italy This supplement was not sponsored by outside commercial interests.. It was funded entirely by the publisher.. Acknowledgements* Gold Sponsors Silver Sponsor Bronze Sponsor Other Sponsors *Confirmed sponsors as of May 6th 2025.

    Article Title: Solution conformational differences between conventional and CENP-A nucleosomes are accentuated by reversible deformation under high pressure
    Article Snippet: Since the 1970 s, small-angle scattering (SAS) has served as an invaluable complementary tool for structural biology that has bridged the gap between atomic-level structure and solution behavior (Mohammed et al. ; Weiss ).

    Article Title: Molecular insights: How counterions determine surfactant aggregation.
    Article Snippet: The morphology of surfactant aggregates inherently determines their properties and functions.. Hence, the modulation of morphology holds significant importance in their applications.. Opting for an appropriate counterion emerges as an efficient and convenient method to shape the aggregate morphology of ionic surfactants.

    Spectroscopy:

    Article Title: Recent Progress of Artificial Intelligence Application in Polymer Materials
    Article Snippet: Their applications involve the composition optimization [ ], experiment cost deduction [ ], properties prediction (including Young’s modulus [ ], melting temperature [ , ], thermal stability, and thermal conductivity [ , ]), and characterization analysis (such as powder diffraction (PD), pair distribution function (PDF), small-angle scattering (SAS), inelastic neutron scattering (INS), and X-ray absorption spectroscopy (XAS) [ , ]).

    Article Title: Fast calculation of small-angle scattering profiles of dense protein solutions modeled at the all-atom level
    Article Snippet: Small-angle scattering (SAS) is a uniquely powerful technique for probing the internal structures of proteins and interprotein interactions.

    Article Title: Solution conformational differences between conventional and CENP-A nucleosomes are accentuated by reversible deformation under high pressure.
    Article Snippet: Since the 1970 s, small-angle scattering (SAS) has served as an invaluable complementary tool for structural biology that has bridged the gap between atomic-level structure and solution behavior (Mohammed et al. 2024; Weiss 2017).

    Article Title: Reconfigurable Soft Actuators Constructed via Layer‐by‐layer Assembly
    Article Snippet: To study the structural basis of the stimuli-sensitivity of the two films, small-angle scattering (SAS) experiments are performed, including small-angle X-ray scattering (SAXS) and small-angle neutron scattering (SANS) (Figure S2, Supporting Information).

    Article Title: 15th EBSA congress, June 30 - July 4, 2025, Rome, Italy - Abstracts.
    Article Snippet: European Biophysics Journal (2025) 54 (Suppl 1):S1–S273 https://doi.org/10.1007/s00249-025-01757-9 15th EBSA congress June 30 – July 4, 2025, Rome, Italy This supplement was not sponsored by outside commercial interests.. It was funded entirely by the publisher.. Acknowledgements* Gold Sponsors Silver Sponsor Bronze Sponsor Other Sponsors *Confirmed sponsors as of May 6th 2025.

    Article Title: Solution conformational differences between conventional and CENP-A nucleosomes are accentuated by reversible deformation under high pressure
    Article Snippet: Since the 1970 s, small-angle scattering (SAS) has served as an invaluable complementary tool for structural biology that has bridged the gap between atomic-level structure and solution behavior (Mohammed et al. ; Weiss ).

    Article Title: Molecular insights: How counterions determine surfactant aggregation.
    Article Snippet: The morphology of surfactant aggregates inherently determines their properties and functions.. Hence, the modulation of morphology holds significant importance in their applications.. Opting for an appropriate counterion emerges as an efficient and convenient method to shape the aggregate morphology of ionic surfactants.

    Förster Resonance Energy Transfer:

    Article Title: Recent Progress of Artificial Intelligence Application in Polymer Materials
    Article Snippet: Their applications involve the composition optimization [ ], experiment cost deduction [ ], properties prediction (including Young’s modulus [ ], melting temperature [ , ], thermal stability, and thermal conductivity [ , ]), and characterization analysis (such as powder diffraction (PD), pair distribution function (PDF), small-angle scattering (SAS), inelastic neutron scattering (INS), and X-ray absorption spectroscopy (XAS) [ , ]).

    Article Title: Fast calculation of small-angle scattering profiles of dense protein solutions modeled at the all-atom level
    Article Snippet: Small-angle scattering (SAS) is a uniquely powerful technique for probing the internal structures of proteins and interprotein interactions.

    Article Title: Solution conformational differences between conventional and CENP-A nucleosomes are accentuated by reversible deformation under high pressure.
    Article Snippet: Since the 1970 s, small-angle scattering (SAS) has served as an invaluable complementary tool for structural biology that has bridged the gap between atomic-level structure and solution behavior (Mohammed et al. 2024; Weiss 2017).

    Article Title: Reconfigurable Soft Actuators Constructed via Layer‐by‐layer Assembly
    Article Snippet: To study the structural basis of the stimuli-sensitivity of the two films, small-angle scattering (SAS) experiments are performed, including small-angle X-ray scattering (SAXS) and small-angle neutron scattering (SANS) (Figure S2, Supporting Information).

    Article Title: 15th EBSA congress, June 30 - July 4, 2025, Rome, Italy - Abstracts.
    Article Snippet: European Biophysics Journal (2025) 54 (Suppl 1):S1–S273 https://doi.org/10.1007/s00249-025-01757-9 15th EBSA congress June 30 – July 4, 2025, Rome, Italy This supplement was not sponsored by outside commercial interests.. It was funded entirely by the publisher.. Acknowledgements* Gold Sponsors Silver Sponsor Bronze Sponsor Other Sponsors *Confirmed sponsors as of May 6th 2025.

    Article Title: Solution conformational differences between conventional and CENP-A nucleosomes are accentuated by reversible deformation under high pressure
    Article Snippet: Since the 1970 s, small-angle scattering (SAS) has served as an invaluable complementary tool for structural biology that has bridged the gap between atomic-level structure and solution behavior (Mohammed et al. ; Weiss ).

    Article Title: Molecular insights: How counterions determine surfactant aggregation.
    Article Snippet: The morphology of surfactant aggregates inherently determines their properties and functions.. Hence, the modulation of morphology holds significant importance in their applications.. Opting for an appropriate counterion emerges as an efficient and convenient method to shape the aggregate morphology of ionic surfactants.



    Similar Products

    86
    Inscopix Inc data processing software idps
    Data Processing Software Idps, supplied by Inscopix Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/data+processing+software+idps/data+processing+software/bio_rxiv__64898__2026__06__02__729661-381-6-5
    Average 86 stars, based on 1 article reviews
    data processing software idps - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    90
    Inscopix Inc data processing software (idps)
    Data Processing Software (Idps), supplied by Inscopix Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/data+processing+software+idps/data+processing+software/pmc12275950-19-1-0
    Average 90 stars, based on 1 article reviews
    data processing software (idps) - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Inscopix Inc idps (inscopix data processing software)
    Idps (Inscopix Data Processing Software), supplied by Inscopix Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/data+processing+software+idps/idps++inscopix+data+processing+software+/pmc12192352-285-15-16
    Average 90 stars, based on 1 article reviews
    idps (inscopix data processing software) - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Inscopix Inc data processing software idps v1.9.1
    Data Processing Software Idps V1.9.1, supplied by Inscopix Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/data+processing+software+idps/data+processing+software+idps+v1+9+1/pmc12138423-292-23-23
    Average 90 stars, based on 1 article reviews
    data processing software idps v1.9.1 - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Inscopix Inc data processing software idps 1.8.0
    a , Simultaneous in vivo calcium imaging and optogenetic stimulation under free-moving conditions. AAV-syn-GCaMP6f and AAV-syn-ChrimsonR were co-injected into the DG, followed by GRIN-lens implantation. An integrated miniature microscope (nVoke; <t>Inscopix)</t> enabled large-scale cellular-resolution Ca 2+ imaging and optogenetic stimulation. b, Left: Expression of GCaMP6f and ChrimsonR in the DG. Right: Max projection of relative fluorescence change (Δ F / F ) of Ca 2+ transients from all imaging frames during the first 30 min, showing representative active neurons. c, Top: Experimental design of Ca 2+ imaging combined with optogenetic stimulation during the open field test. Each 50-min session consisted of 30-min Ca 2+ imaging (used for the following analysis), 5-min optogenetic stimulation, and 15-min post-stimulation recording. This was repeated for 10 days. No light was introduced to mice in the No Stim group. Bottom: Δ F / F traces from 15 representative neurons (scale bar, 10% Δ F / F ). <t>Data</t> from 25 to 38 min of a 50-min session are shown. d, Distance traveled during the first 30 min e, Average Ca 2+ transient rate during the first 30 min. f, Distribution of spatial information for the No Stim (grey curve) and Stim×10 groups (red curve). The vertical axis represents the frequency of distribution, with the dotted line indicating the criterion for place cells (top 95% percentile of the shuffled distribution; see Methods section). Bar graph indicates proportion of place cells. g, Representative results of position decoding using Ca 2+ imaging data. The first 30 min was split into two 15-min halves for training and test data for decoding. Black/red lines: observed position; grey/pink lines: decoded position. h, Decoding accuracy (mae; mean absolute error, cm). Dotted lines: shuffled control. Two-way repeated measures ANOVA: Stim type, F (1, 8) = 6.49, P = 0.034; Day, F (2, 16) = 2.89, P = 0.085; Stim type × Day, F (2, 16) = 1.11, P = 0.353. Bonferroni correction for multiple comparisons was performed, * P < 0.05. i, Same as f , but for speed information and speed cells. The dotted line indicates the criterion for speed cells (top 99% percentile of the shuffled distribution). j, Same as g , but for speed decoding. k, Same as h , but for speed decoding accuracy. Two-way repeated measures ANOVA: Stim type, F (1, 8) =4.02, P = 0.080; Day, F (2, 16) = 4.87, P = 0.022; Day×Stim type, F (2, 16) = 3.98, P = 0.039. Bonferroni correction for multiple comparisons was performed, * P < 0.05.
    Data Processing Software Idps 1.8.0, supplied by Inscopix Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/data+processing+software+idps/data+processing+software+idps+v1+9+1/bio_rxiv__2025__05__02__651848-361-16-16
    Average 90 stars, based on 1 article reviews
    data processing software idps 1.8.0 - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Inscopix Inc idps inscopix data 721 processing software
    a , Simultaneous in vivo calcium imaging and optogenetic stimulation under free-moving conditions. AAV-syn-GCaMP6f and AAV-syn-ChrimsonR were co-injected into the DG, followed by GRIN-lens implantation. An integrated miniature microscope (nVoke; <t>Inscopix)</t> enabled large-scale cellular-resolution Ca 2+ imaging and optogenetic stimulation. b, Left: Expression of GCaMP6f and ChrimsonR in the DG. Right: Max projection of relative fluorescence change (Δ F / F ) of Ca 2+ transients from all imaging frames during the first 30 min, showing representative active neurons. c, Top: Experimental design of Ca 2+ imaging combined with optogenetic stimulation during the open field test. Each 50-min session consisted of 30-min Ca 2+ imaging (used for the following analysis), 5-min optogenetic stimulation, and 15-min post-stimulation recording. This was repeated for 10 days. No light was introduced to mice in the No Stim group. Bottom: Δ F / F traces from 15 representative neurons (scale bar, 10% Δ F / F ). <t>Data</t> from 25 to 38 min of a 50-min session are shown. d, Distance traveled during the first 30 min e, Average Ca 2+ transient rate during the first 30 min. f, Distribution of spatial information for the No Stim (grey curve) and Stim×10 groups (red curve). The vertical axis represents the frequency of distribution, with the dotted line indicating the criterion for place cells (top 95% percentile of the shuffled distribution; see Methods section). Bar graph indicates proportion of place cells. g, Representative results of position decoding using Ca 2+ imaging data. The first 30 min was split into two 15-min halves for training and test data for decoding. Black/red lines: observed position; grey/pink lines: decoded position. h, Decoding accuracy (mae; mean absolute error, cm). Dotted lines: shuffled control. Two-way repeated measures ANOVA: Stim type, F (1, 8) = 6.49, P = 0.034; Day, F (2, 16) = 2.89, P = 0.085; Stim type × Day, F (2, 16) = 1.11, P = 0.353. Bonferroni correction for multiple comparisons was performed, * P < 0.05. i, Same as f , but for speed information and speed cells. The dotted line indicates the criterion for speed cells (top 99% percentile of the shuffled distribution). j, Same as g , but for speed decoding. k, Same as h , but for speed decoding accuracy. Two-way repeated measures ANOVA: Stim type, F (1, 8) =4.02, P = 0.080; Day, F (2, 16) = 4.87, P = 0.022; Day×Stim type, F (2, 16) = 3.98, P = 0.039. Bonferroni correction for multiple comparisons was performed, * P < 0.05.
    Idps Inscopix Data 721 Processing Software, supplied by Inscopix Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/data+processing+software+idps/idps+inscopix+data+721+processing+software/pm40157920-532-8-9
    Average 90 stars, based on 1 article reviews
    idps inscopix data 721 processing software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    a , Simultaneous in vivo calcium imaging and optogenetic stimulation under free-moving conditions. AAV-syn-GCaMP6f and AAV-syn-ChrimsonR were co-injected into the DG, followed by GRIN-lens implantation. An integrated miniature microscope (nVoke; Inscopix) enabled large-scale cellular-resolution Ca 2+ imaging and optogenetic stimulation. b, Left: Expression of GCaMP6f and ChrimsonR in the DG. Right: Max projection of relative fluorescence change (Δ F / F ) of Ca 2+ transients from all imaging frames during the first 30 min, showing representative active neurons. c, Top: Experimental design of Ca 2+ imaging combined with optogenetic stimulation during the open field test. Each 50-min session consisted of 30-min Ca 2+ imaging (used for the following analysis), 5-min optogenetic stimulation, and 15-min post-stimulation recording. This was repeated for 10 days. No light was introduced to mice in the No Stim group. Bottom: Δ F / F traces from 15 representative neurons (scale bar, 10% Δ F / F ). Data from 25 to 38 min of a 50-min session are shown. d, Distance traveled during the first 30 min e, Average Ca 2+ transient rate during the first 30 min. f, Distribution of spatial information for the No Stim (grey curve) and Stim×10 groups (red curve). The vertical axis represents the frequency of distribution, with the dotted line indicating the criterion for place cells (top 95% percentile of the shuffled distribution; see Methods section). Bar graph indicates proportion of place cells. g, Representative results of position decoding using Ca 2+ imaging data. The first 30 min was split into two 15-min halves for training and test data for decoding. Black/red lines: observed position; grey/pink lines: decoded position. h, Decoding accuracy (mae; mean absolute error, cm). Dotted lines: shuffled control. Two-way repeated measures ANOVA: Stim type, F (1, 8) = 6.49, P = 0.034; Day, F (2, 16) = 2.89, P = 0.085; Stim type × Day, F (2, 16) = 1.11, P = 0.353. Bonferroni correction for multiple comparisons was performed, * P < 0.05. i, Same as f , but for speed information and speed cells. The dotted line indicates the criterion for speed cells (top 99% percentile of the shuffled distribution). j, Same as g , but for speed decoding. k, Same as h , but for speed decoding accuracy. Two-way repeated measures ANOVA: Stim type, F (1, 8) =4.02, P = 0.080; Day, F (2, 16) = 4.87, P = 0.022; Day×Stim type, F (2, 16) = 3.98, P = 0.039. Bonferroni correction for multiple comparisons was performed, * P < 0.05.

    Journal: bioRxiv

    Article Title: Repetitive Neuronal Activation Regulates Cellular Maturation State via Nuclear Reprogramming

    doi: 10.1101/2025.05.02.651848

    Figure Lengend Snippet: a , Simultaneous in vivo calcium imaging and optogenetic stimulation under free-moving conditions. AAV-syn-GCaMP6f and AAV-syn-ChrimsonR were co-injected into the DG, followed by GRIN-lens implantation. An integrated miniature microscope (nVoke; Inscopix) enabled large-scale cellular-resolution Ca 2+ imaging and optogenetic stimulation. b, Left: Expression of GCaMP6f and ChrimsonR in the DG. Right: Max projection of relative fluorescence change (Δ F / F ) of Ca 2+ transients from all imaging frames during the first 30 min, showing representative active neurons. c, Top: Experimental design of Ca 2+ imaging combined with optogenetic stimulation during the open field test. Each 50-min session consisted of 30-min Ca 2+ imaging (used for the following analysis), 5-min optogenetic stimulation, and 15-min post-stimulation recording. This was repeated for 10 days. No light was introduced to mice in the No Stim group. Bottom: Δ F / F traces from 15 representative neurons (scale bar, 10% Δ F / F ). Data from 25 to 38 min of a 50-min session are shown. d, Distance traveled during the first 30 min e, Average Ca 2+ transient rate during the first 30 min. f, Distribution of spatial information for the No Stim (grey curve) and Stim×10 groups (red curve). The vertical axis represents the frequency of distribution, with the dotted line indicating the criterion for place cells (top 95% percentile of the shuffled distribution; see Methods section). Bar graph indicates proportion of place cells. g, Representative results of position decoding using Ca 2+ imaging data. The first 30 min was split into two 15-min halves for training and test data for decoding. Black/red lines: observed position; grey/pink lines: decoded position. h, Decoding accuracy (mae; mean absolute error, cm). Dotted lines: shuffled control. Two-way repeated measures ANOVA: Stim type, F (1, 8) = 6.49, P = 0.034; Day, F (2, 16) = 2.89, P = 0.085; Stim type × Day, F (2, 16) = 1.11, P = 0.353. Bonferroni correction for multiple comparisons was performed, * P < 0.05. i, Same as f , but for speed information and speed cells. The dotted line indicates the criterion for speed cells (top 99% percentile of the shuffled distribution). j, Same as g , but for speed decoding. k, Same as h , but for speed decoding accuracy. Two-way repeated measures ANOVA: Stim type, F (1, 8) =4.02, P = 0.080; Day, F (2, 16) = 4.87, P = 0.022; Day×Stim type, F (2, 16) = 3.98, P = 0.039. Bonferroni correction for multiple comparisons was performed, * P < 0.05.

    Article Snippet: To extract the activity patterns of individual DG neurons from the obtained fluorescent images, we used Inscopix Data Processing Software (IDPS 1.8.0).

    Techniques: In Vivo, Imaging, Injection, Microscopy, Expressing, Fluorescence, Control