Review



smartarrayertm 136 microarrays contact printer  (CapitalBio Corporation)

 
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    CapitalBio Corporation smartarrayertm 136 microarrays contact printer
    Smartarrayertm 136 Microarrays Contact Printer, supplied by CapitalBio Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/contact+microarray+printer/smartarrayertm+136+microarrays+contact+printer/pmc07828587-209-0-2
    Average 90 stars, based on 1 article reviews
    smartarrayertm 136 microarrays contact printer - by Bioz Stars, 2026-11
    90/100 stars

    Images

    Related Articles

    High Throughput Screening Assay:

    Article Title: Systematic Identification of Protein Targets of Sub5 Using Saccharomyces cerevisiae Proteome Microarrays
    Article Snippet: Briefly, using Liquidator 96 manual pipetting system (Mettler Toledo Rainin, LLC, Oakland, CA, USA), Saccharomyces cerevisiae purified proteins in 96-well plates were transferred to 384-well plates. .. High throughput CapitalBio SmartArrayerTM 136 microarrays contact printer (Capitalbio Corporation, Beijing, China) with 48 microarray pins were used for spotting (in duplicate) the entire ~5800 individual Saccharomyces cerevisiae proteins, and several landmark proteins on the aldehyde-coated glass slides to fabricate Saccharomyces cerevisiae proteome microarrays. ..

    Microarray:

    Article Title: Systematic Identification of Protein Targets of Sub5 Using Saccharomyces cerevisiae Proteome Microarrays
    Article Snippet: Briefly, using Liquidator 96 manual pipetting system (Mettler Toledo Rainin, LLC, Oakland, CA, USA), Saccharomyces cerevisiae purified proteins in 96-well plates were transferred to 384-well plates. .. High throughput CapitalBio SmartArrayerTM 136 microarrays contact printer (Capitalbio Corporation, Beijing, China) with 48 microarray pins were used for spotting (in duplicate) the entire ~5800 individual Saccharomyces cerevisiae proteins, and several landmark proteins on the aldehyde-coated glass slides to fabricate Saccharomyces cerevisiae proteome microarrays. ..



    Similar Products

    95
    SCIENION non contact inkjet microarray printer
    The VANC-D4 assay (A) Fabrication of the VANC-D4 assay. SI-ATRP is used to grow POEGMA-co-GMA brushes on glass slides. Following SI-ATRP, VANC-BSA is <t>inkjet</t> printed into the polymer brush to create stable spots and fluorescently labeled anti-VANC antibodies (termed dAb) are printed on trehalose pads to create labile spots. (B) Sequential steps of the VANC-D4 assay. The steps of the VANC-D4 are (i) dispensing a blood sample on the surface, (ii) dissolution of the trehalose pads to release the fluorescently labeled dAb into solution, (iii) diffusion of the labeled dAb in the sample volume, (iv) detection of fluorescence signal from the antibody bound to immobilized VANC-BSA. (C) Representative VANC-D4 assay response in the presence of (i) no drug, (ii) low drug, and (iii) high drug concentration. (D) VANC monitoring across its clinical range using VANC-spiked whole blood diluted 100-fold in running buffer, analyzed in triplicate. The clinical range for the test is 1–45 μg/mL. Intensity values are shown, with error bars that represent the standard error of the means for n = 3 separate runs. The LOD for the presented dose-response curve was calculated to be 0.8 μg/mL.
    Non Contact Inkjet Microarray Printer, supplied by SCIENION, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/contact+microarray+printer/sciFLEXARRAYER+S12/pmc13380757-243-19-23
    Average 95 stars, based on 1 article reviews
    non contact inkjet microarray printer - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    90
    CapitalBio Corporation contact microarray printer smartarrayer 136
    The VANC-D4 assay (A) Fabrication of the VANC-D4 assay. SI-ATRP is used to grow POEGMA-co-GMA brushes on glass slides. Following SI-ATRP, VANC-BSA is <t>inkjet</t> printed into the polymer brush to create stable spots and fluorescently labeled anti-VANC antibodies (termed dAb) are printed on trehalose pads to create labile spots. (B) Sequential steps of the VANC-D4 assay. The steps of the VANC-D4 are (i) dispensing a blood sample on the surface, (ii) dissolution of the trehalose pads to release the fluorescently labeled dAb into solution, (iii) diffusion of the labeled dAb in the sample volume, (iv) detection of fluorescence signal from the antibody bound to immobilized VANC-BSA. (C) Representative VANC-D4 assay response in the presence of (i) no drug, (ii) low drug, and (iii) high drug concentration. (D) VANC monitoring across its clinical range using VANC-spiked whole blood diluted 100-fold in running buffer, analyzed in triplicate. The clinical range for the test is 1–45 μg/mL. Intensity values are shown, with error bars that represent the standard error of the means for n = 3 separate runs. The LOD for the presented dose-response curve was calculated to be 0.8 μg/mL.
    Contact Microarray Printer Smartarrayer 136, supplied by CapitalBio Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/contact+microarray+printer/contact+microarray+printer+smartarrayer+136/pm40249703-755-24-29
    Average 90 stars, based on 1 article reviews
    contact microarray printer smartarrayer 136 - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    SCIENION sciflexarrayer s1 non-contact microarray printer
    The VANC-D4 assay (A) Fabrication of the VANC-D4 assay. SI-ATRP is used to grow POEGMA-co-GMA brushes on glass slides. Following SI-ATRP, VANC-BSA is <t>inkjet</t> printed into the polymer brush to create stable spots and fluorescently labeled anti-VANC antibodies (termed dAb) are printed on trehalose pads to create labile spots. (B) Sequential steps of the VANC-D4 assay. The steps of the VANC-D4 are (i) dispensing a blood sample on the surface, (ii) dissolution of the trehalose pads to release the fluorescently labeled dAb into solution, (iii) diffusion of the labeled dAb in the sample volume, (iv) detection of fluorescence signal from the antibody bound to immobilized VANC-BSA. (C) Representative VANC-D4 assay response in the presence of (i) no drug, (ii) low drug, and (iii) high drug concentration. (D) VANC monitoring across its clinical range using VANC-spiked whole blood diluted 100-fold in running buffer, analyzed in triplicate. The clinical range for the test is 1–45 μg/mL. Intensity values are shown, with error bars that represent the standard error of the means for n = 3 separate runs. The LOD for the presented dose-response curve was calculated to be 0.8 μg/mL.
    Sciflexarrayer S1 Non Contact Microarray Printer, supplied by SCIENION, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/contact+microarray+printer/noncontact+microarray+spotter+sciflexarrayer+s12/pmc11673104__ja4c08817_si_001-501-8-7
    Average 90 stars, based on 1 article reviews
    sciflexarrayer s1 non-contact microarray printer - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    SCIENION s-11 non-contact microarray printer
    The VANC-D4 assay (A) Fabrication of the VANC-D4 assay. SI-ATRP is used to grow POEGMA-co-GMA brushes on glass slides. Following SI-ATRP, VANC-BSA is <t>inkjet</t> printed into the polymer brush to create stable spots and fluorescently labeled anti-VANC antibodies (termed dAb) are printed on trehalose pads to create labile spots. (B) Sequential steps of the VANC-D4 assay. The steps of the VANC-D4 are (i) dispensing a blood sample on the surface, (ii) dissolution of the trehalose pads to release the fluorescently labeled dAb into solution, (iii) diffusion of the labeled dAb in the sample volume, (iv) detection of fluorescence signal from the antibody bound to immobilized VANC-BSA. (C) Representative VANC-D4 assay response in the presence of (i) no drug, (ii) low drug, and (iii) high drug concentration. (D) VANC monitoring across its clinical range using VANC-spiked whole blood diluted 100-fold in running buffer, analyzed in triplicate. The clinical range for the test is 1–45 μg/mL. Intensity values are shown, with error bars that represent the standard error of the means for n = 3 separate runs. The LOD for the presented dose-response curve was calculated to be 0.8 μg/mL.
    S 11 Non Contact Microarray Printer, supplied by SCIENION, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/contact+microarray+printer/noncontact+microarray+printer/us12038446-634-19-19
    Average 90 stars, based on 1 article reviews
    s-11 non-contact microarray printer - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    96
    SCIENION sciflexarrayer s3 non contact microarray printer
    The VANC-D4 assay (A) Fabrication of the VANC-D4 assay. SI-ATRP is used to grow POEGMA-co-GMA brushes on glass slides. Following SI-ATRP, VANC-BSA is <t>inkjet</t> printed into the polymer brush to create stable spots and fluorescently labeled anti-VANC antibodies (termed dAb) are printed on trehalose pads to create labile spots. (B) Sequential steps of the VANC-D4 assay. The steps of the VANC-D4 are (i) dispensing a blood sample on the surface, (ii) dissolution of the trehalose pads to release the fluorescently labeled dAb into solution, (iii) diffusion of the labeled dAb in the sample volume, (iv) detection of fluorescence signal from the antibody bound to immobilized VANC-BSA. (C) Representative VANC-D4 assay response in the presence of (i) no drug, (ii) low drug, and (iii) high drug concentration. (D) VANC monitoring across its clinical range using VANC-spiked whole blood diluted 100-fold in running buffer, analyzed in triplicate. The clinical range for the test is 1–45 μg/mL. Intensity values are shown, with error bars that represent the standard error of the means for n = 3 separate runs. The LOD for the presented dose-response curve was calculated to be 0.8 μg/mL.
    Sciflexarrayer S3 Non Contact Microarray Printer, supplied by SCIENION, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/contact+microarray+printer/sciFLEXARRAYER+S3/pmc10900492__au3c00695_si_001-339-7-6
    Average 96 stars, based on 1 article reviews
    sciflexarrayer s3 non contact microarray printer - by Bioz Stars, 2026-11
    96/100 stars
      Buy from Supplier

    90
    BioDot Inc contact microarray printer
    The VANC-D4 assay (A) Fabrication of the VANC-D4 assay. SI-ATRP is used to grow POEGMA-co-GMA brushes on glass slides. Following SI-ATRP, VANC-BSA is <t>inkjet</t> printed into the polymer brush to create stable spots and fluorescently labeled anti-VANC antibodies (termed dAb) are printed on trehalose pads to create labile spots. (B) Sequential steps of the VANC-D4 assay. The steps of the VANC-D4 are (i) dispensing a blood sample on the surface, (ii) dissolution of the trehalose pads to release the fluorescently labeled dAb into solution, (iii) diffusion of the labeled dAb in the sample volume, (iv) detection of fluorescence signal from the antibody bound to immobilized VANC-BSA. (C) Representative VANC-D4 assay response in the presence of (i) no drug, (ii) low drug, and (iii) high drug concentration. (D) VANC monitoring across its clinical range using VANC-spiked whole blood diluted 100-fold in running buffer, analyzed in triplicate. The clinical range for the test is 1–45 μg/mL. Intensity values are shown, with error bars that represent the standard error of the means for n = 3 separate runs. The LOD for the presented dose-response curve was calculated to be 0.8 μg/mL.
    Contact Microarray Printer, supplied by BioDot Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/contact+microarray+printer/contact+microarray+printer/pmc10688221__ac3c03887_si_001-39-13-16
    Average 90 stars, based on 1 article reviews
    contact microarray printer - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    The VANC-D4 assay (A) Fabrication of the VANC-D4 assay. SI-ATRP is used to grow POEGMA-co-GMA brushes on glass slides. Following SI-ATRP, VANC-BSA is inkjet printed into the polymer brush to create stable spots and fluorescently labeled anti-VANC antibodies (termed dAb) are printed on trehalose pads to create labile spots. (B) Sequential steps of the VANC-D4 assay. The steps of the VANC-D4 are (i) dispensing a blood sample on the surface, (ii) dissolution of the trehalose pads to release the fluorescently labeled dAb into solution, (iii) diffusion of the labeled dAb in the sample volume, (iv) detection of fluorescence signal from the antibody bound to immobilized VANC-BSA. (C) Representative VANC-D4 assay response in the presence of (i) no drug, (ii) low drug, and (iii) high drug concentration. (D) VANC monitoring across its clinical range using VANC-spiked whole blood diluted 100-fold in running buffer, analyzed in triplicate. The clinical range for the test is 1–45 μg/mL. Intensity values are shown, with error bars that represent the standard error of the means for n = 3 separate runs. The LOD for the presented dose-response curve was calculated to be 0.8 μg/mL.

    Journal: iScience

    Article Title: A rapid point-of-care test for vancomycin monitoring at the clinical bedside

    doi: 10.1016/j.isci.2026.116064

    Figure Lengend Snippet: The VANC-D4 assay (A) Fabrication of the VANC-D4 assay. SI-ATRP is used to grow POEGMA-co-GMA brushes on glass slides. Following SI-ATRP, VANC-BSA is inkjet printed into the polymer brush to create stable spots and fluorescently labeled anti-VANC antibodies (termed dAb) are printed on trehalose pads to create labile spots. (B) Sequential steps of the VANC-D4 assay. The steps of the VANC-D4 are (i) dispensing a blood sample on the surface, (ii) dissolution of the trehalose pads to release the fluorescently labeled dAb into solution, (iii) diffusion of the labeled dAb in the sample volume, (iv) detection of fluorescence signal from the antibody bound to immobilized VANC-BSA. (C) Representative VANC-D4 assay response in the presence of (i) no drug, (ii) low drug, and (iii) high drug concentration. (D) VANC monitoring across its clinical range using VANC-spiked whole blood diluted 100-fold in running buffer, analyzed in triplicate. The clinical range for the test is 1–45 μg/mL. Intensity values are shown, with error bars that represent the standard error of the means for n = 3 separate runs. The LOD for the presented dose-response curve was calculated to be 0.8 μg/mL.

    Article Snippet: Following polymerization, D4 assays were fabricated using non-contact inkjet printing methods as described elsewhere., VANC-BSA was printed using a non-contact inkjet microarray printer (Scienion, sciFLEXARRAYER Type S12).

    Techniques: Polymer, Labeling, Dissolution, Diffusion-based Assay, Fluorescence, Concentration Assay