Review



first generation photon counting detector computed tomography pcd ct scanner  (Siemens Healthineers)

 
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 86

    Structured Review

    Siemens Healthineers first generation photon counting detector computed tomography pcd ct scanner
    <t>PCD-CT</t> <t>Visualizing</t> a Left Ventricular Pseudoaneurysm and Inferior Myocardial Infarction (A and B) A left ventricular pseudoaneurysm with intraluminal thrombus (blue arrows in B) is visualized, accompanied by a significant amount of pericardial effusion (asterisk in B). (C) Late enhancement acquisition using iodinated contrast shows an increased signal of the inferior myocardial wall apical of the pseudoaneurysm on a calculated iodine map (orange arrow) and (D) an extracellular volume map (arrow), indicating myocardial fibrosis. On the iodine map, an increased signal surrounding the aneurysm is visualized (white arrows in C), suggestive of pericardial involvement. CCTA = cardiac computed tomography angiography; ECV = extracellular volume; LV = left ventricle; PA = pseudoaneurysm.
    First Generation Photon Counting Detector Computed Tomography Pcd Ct Scanner, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/computer+generated/counting+photon/pmc12926192-27-5-14
    Average 86 stars, based on 1 article reviews
    first generation photon counting detector computed tomography pcd ct scanner - by Bioz Stars, 2026-11
    86/100 stars

    Images

    1) Product Images from "Characterizing a Left Ventricular Pseudoaneurysm With Photon-Counting Detector CT"

    Article Title: Characterizing a Left Ventricular Pseudoaneurysm With Photon-Counting Detector CT

    Journal: JACC Case Reports

    doi: 10.1016/j.jaccas.2025.106238

    PCD-CT Visualizing a Left Ventricular Pseudoaneurysm and Inferior Myocardial Infarction (A and B) A left ventricular pseudoaneurysm with intraluminal thrombus (blue arrows in B) is visualized, accompanied by a significant amount of pericardial effusion (asterisk in B). (C) Late enhancement acquisition using iodinated contrast shows an increased signal of the inferior myocardial wall apical of the pseudoaneurysm on a calculated iodine map (orange arrow) and (D) an extracellular volume map (arrow), indicating myocardial fibrosis. On the iodine map, an increased signal surrounding the aneurysm is visualized (white arrows in C), suggestive of pericardial involvement. CCTA = cardiac computed tomography angiography; ECV = extracellular volume; LV = left ventricle; PA = pseudoaneurysm.
    Figure Legend Snippet: PCD-CT Visualizing a Left Ventricular Pseudoaneurysm and Inferior Myocardial Infarction (A and B) A left ventricular pseudoaneurysm with intraluminal thrombus (blue arrows in B) is visualized, accompanied by a significant amount of pericardial effusion (asterisk in B). (C) Late enhancement acquisition using iodinated contrast shows an increased signal of the inferior myocardial wall apical of the pseudoaneurysm on a calculated iodine map (orange arrow) and (D) an extracellular volume map (arrow), indicating myocardial fibrosis. On the iodine map, an increased signal surrounding the aneurysm is visualized (white arrows in C), suggestive of pericardial involvement. CCTA = cardiac computed tomography angiography; ECV = extracellular volume; LV = left ventricle; PA = pseudoaneurysm.

    Techniques Used: Computed Tomography

    Photon-Counting Detector CCTA Photon-counting detector CCTA image demonstrating a pseudoaneurysm of the inferoseptal myocardial wall, occlusion of the right coronary artery (blue arrow), and pericardial effusion (asterisk). CCTA = cardiac computed tomography angiography; PA = pseudoaneurysm.
    Figure Legend Snippet: Photon-Counting Detector CCTA Photon-counting detector CCTA image demonstrating a pseudoaneurysm of the inferoseptal myocardial wall, occlusion of the right coronary artery (blue arrow), and pericardial effusion (asterisk). CCTA = cardiac computed tomography angiography; PA = pseudoaneurysm.

    Techniques Used: Computed Tomography

    Short-Axis Comparison Between CMR and PCD-CT Findings The basal short-axis slices (upper row) show late enhancement surrounding the pseudoaneurysm, while the mid slices (middle row) show late enhancement of the inferior wall below the pseudoaneurysm. The apical slices (lower row) do not show any enhancement of the myocardium. A stack artifact in the PCD-CT images seems to cause a horizontal line of increased ECV in the mid/apical short axis slice. T2-weigted CMR images do not include a hyperintense signal in the infarcted myocardium, indicating the absence of myocardial edema and confirming the chronic stage of the infarction. A hyperintense signal of the pericardium is visible, consistent with active pericarditis. CMR = cardiac magnetic resonance imaging; ECV = extracellular volume; LGE = late gadolinium enhancement; PCD-CT = photon-counting detector computed tomography.
    Figure Legend Snippet: Short-Axis Comparison Between CMR and PCD-CT Findings The basal short-axis slices (upper row) show late enhancement surrounding the pseudoaneurysm, while the mid slices (middle row) show late enhancement of the inferior wall below the pseudoaneurysm. The apical slices (lower row) do not show any enhancement of the myocardium. A stack artifact in the PCD-CT images seems to cause a horizontal line of increased ECV in the mid/apical short axis slice. T2-weigted CMR images do not include a hyperintense signal in the infarcted myocardium, indicating the absence of myocardial edema and confirming the chronic stage of the infarction. A hyperintense signal of the pericardium is visible, consistent with active pericarditis. CMR = cardiac magnetic resonance imaging; ECV = extracellular volume; LGE = late gadolinium enhancement; PCD-CT = photon-counting detector computed tomography.

    Techniques Used: Comparison, Magnetic Resonance Imaging, Computed Tomography

    Related Articles

    other:

    Article Title: First Complete Morphological Description of Schistosoma Reflexum in a Llama
    Article Snippet: A complete computed tomographic examination was performed with a photon counting computed tomographic scanner (Naeotom Alpha, Siemens Healthineers, Zurich, Switzerland) at the Division of Clinical Radiology, Vetsuisse‐Faculty, University of Bern, using 140 kVp and 364 mA, a pitch of 0.9 and a single collimation width of 0.4 mm.

    Article Title: Clinical Utility and Limitations of Photon-Counting Detector CTA in the Follow-Up of Flow Diverter Stent
    Article Snippet: Photon-counting detector CT (PCD-CT; NAEOTOM Alpha, Syngo CT VA50; Siemens Healthcare GmbH, Forchheim, Germany) has recently been introduced and offers superior image quality compared with conventional EID-CT due to higher spatial resolution, improved contrast-to-noise ratio, reduced electronic noise, and greater dose efficiency., ) The utility of PCD-CT for follow-up evaluation of coronary stents has been reported ) ; however, evidence regarding its application to intracranial FD assessment remains limited. )

    Article Title: First Complete Morphological Description of Schistosoma Reflexum in a Llama.
    Article Snippet: A complete computed tomographic examination was performed with a photon counting computed tomographic scanner (Naeotom Alpha, Siemens Healthineers, Zurich, Switzerland) at the Division of Clinical Radiology, Vetsuisse-Faculty, University of Bern, using 140 kVp and 364 mA, a pitch of 0.9 and a single collimation width of 0.4 mm.

    Article Title: Lesion conspicuity assessment of prone 40-keV virtual monoenergetic imaging in arterial-phase photon-counting CT for breast cancer: a retrospective comparison with DCE-MRI.
    Article Snippet: Acknowledgements We thank Mr. Kenichi Nakao (Siemens Healthineers) for technical advice regarding photon-counting CT and international developments, and Mr. Takuya Fujiwara for supporting the syngo.via environment used in this study.

    Article Title: Evaluation of patient-reported outcomes in coronary CT angiography versus invasive coronary angiography
    Article Snippet: CT examinations were performed on a Dual-Source CT (Somatom Force, Siemens Healthineers, Erlangen, Germany) or a dedicated first-generation clinical Photon-Counting CT (Naeotom Alpha, Siemens Healthineers, Erlangen, Germany).

    Article Title: Photon counting detector CT contrast agent-reduced transcatheter aortic valve reconstruction planning: a comparative study.
    Article Snippet: In a single-center, retrospective study design, patients receiving a CT for TAVR planning between January 2022 and September 2023 on a photon-counting detector CT (NAEOTOM Alpha, Siemens Healthcare GmbH, VA50) were included in this study.

    Article Title: Influence of Tube Voltage, Tin Filtration, and Sex on Radiation Dose and Image Quality in Adult Chest Photon-Counting CT: A Phantom-Based Signal-to-Noise-Based Analysis.
    Article Snippet: All scans were performed using a photon-counting CTsystem (Naeotom Alpha, Siemens Healthineers, Erlangen, Germany).

    Article Title: Detection of Hemorrhagic Transformation of Cerebral Infarcts with Ultra-low Field MRI.
    Article Snippet: CT examinations were performed using either a 40-slice scanner (SOMATOM AS, Siemens Healthineers) or a photon-counting CT system (NAEOTOMAlpha, Siemens Healthineers), following standard clinical protocols.



    Similar Products

    86
    Siemens Healthineers generation dual source computed tomography
    Generation Dual Source Computed Tomography, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/computer+generated/ct+dual+scanner+source/pmc13247895-128-16-24
    Average 86 stars, based on 1 article reviews
    generation dual source computed tomography - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    86
    Minitab Inc computer generated randomization list
    Computer Generated Randomization List, supplied by Minitab Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/computer+generated/computer+generated+list+randomization/pmc13055410-66-10-25
    Average 86 stars, based on 1 article reviews
    computer generated randomization list - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    99
    STATA Corporation computer generated randomization sequence
    Computer Generated Randomization Sequence, supplied by STATA Corporation, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/computer+generated/STATA+16%2E0/pm41906101-74-23-26
    Average 99 stars, based on 1 article reviews
    computer generated randomization sequence - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    86
    Hewlett-Packard general purpose computers
    General Purpose Computers, supplied by Hewlett-Packard, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/computer+generated/bus+general+gpib+interface+purpose/us12580989-252-17-29
    Average 86 stars, based on 1 article reviews
    general purpose computers - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    86
    Philips Healthcare third generation spectral detector computed tomography system
    Third Generation Spectral Detector Computed Tomography System, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/computer+generated/aperture+computed+large+machine+positioning+simulation+tomography/pmc13033540-160-5-12
    Average 86 stars, based on 1 article reviews
    third generation spectral detector computed tomography system - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    86
    Fujimori Kogyo computable general equilibrium models
    Computable General Equilibrium Models, supplied by Fujimori Kogyo, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/computer+generated/action+climate+iclap+integrated+model+planning/10__5194_slash_gmd___19___2039___2026-232-2-6
    Average 86 stars, based on 1 article reviews
    computable general equilibrium models - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    86
    Siemens Healthineers third generation dual source computed tomography ct scanner
    Third Generation Dual Source Computed Tomography Ct Scanner, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/computer+generated/ct+dual+scanner+source/pmc12835984-132-6-14
    Average 86 stars, based on 1 article reviews
    third generation dual source computed tomography ct scanner - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    86
    Siemens Healthineers first generation photon counting detector computed tomography pcd ct scanner
    <t>PCD-CT</t> <t>Visualizing</t> a Left Ventricular Pseudoaneurysm and Inferior Myocardial Infarction (A and B) A left ventricular pseudoaneurysm with intraluminal thrombus (blue arrows in B) is visualized, accompanied by a significant amount of pericardial effusion (asterisk in B). (C) Late enhancement acquisition using iodinated contrast shows an increased signal of the inferior myocardial wall apical of the pseudoaneurysm on a calculated iodine map (orange arrow) and (D) an extracellular volume map (arrow), indicating myocardial fibrosis. On the iodine map, an increased signal surrounding the aneurysm is visualized (white arrows in C), suggestive of pericardial involvement. CCTA = cardiac computed tomography angiography; ECV = extracellular volume; LV = left ventricle; PA = pseudoaneurysm.
    First Generation Photon Counting Detector Computed Tomography Pcd Ct Scanner, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/computer+generated/counting+photon/pmc12926192-27-5-14
    Average 86 stars, based on 1 article reviews
    first generation photon counting detector computed tomography pcd ct scanner - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    86
    Siemens Healthineers second generation dual source computed tomography ct system
    <t>PCD-CT</t> <t>Visualizing</t> a Left Ventricular Pseudoaneurysm and Inferior Myocardial Infarction (A and B) A left ventricular pseudoaneurysm with intraluminal thrombus (blue arrows in B) is visualized, accompanied by a significant amount of pericardial effusion (asterisk in B). (C) Late enhancement acquisition using iodinated contrast shows an increased signal of the inferior myocardial wall apical of the pseudoaneurysm on a calculated iodine map (orange arrow) and (D) an extracellular volume map (arrow), indicating myocardial fibrosis. On the iodine map, an increased signal surrounding the aneurysm is visualized (white arrows in C), suggestive of pericardial involvement. CCTA = cardiac computed tomography angiography; ECV = extracellular volume; LV = left ventricle; PA = pseudoaneurysm.
    Second Generation Dual Source Computed Tomography Ct System, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/computer+generated/ct+dual+scanner+source/10__4244_slash_eij___d___25___00671-37-5-14
    Average 86 stars, based on 1 article reviews
    second generation dual source computed tomography ct system - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    Image Search Results


    PCD-CT Visualizing a Left Ventricular Pseudoaneurysm and Inferior Myocardial Infarction (A and B) A left ventricular pseudoaneurysm with intraluminal thrombus (blue arrows in B) is visualized, accompanied by a significant amount of pericardial effusion (asterisk in B). (C) Late enhancement acquisition using iodinated contrast shows an increased signal of the inferior myocardial wall apical of the pseudoaneurysm on a calculated iodine map (orange arrow) and (D) an extracellular volume map (arrow), indicating myocardial fibrosis. On the iodine map, an increased signal surrounding the aneurysm is visualized (white arrows in C), suggestive of pericardial involvement. CCTA = cardiac computed tomography angiography; ECV = extracellular volume; LV = left ventricle; PA = pseudoaneurysm.

    Journal: JACC Case Reports

    Article Title: Characterizing a Left Ventricular Pseudoaneurysm With Photon-Counting Detector CT

    doi: 10.1016/j.jaccas.2025.106238

    Figure Lengend Snippet: PCD-CT Visualizing a Left Ventricular Pseudoaneurysm and Inferior Myocardial Infarction (A and B) A left ventricular pseudoaneurysm with intraluminal thrombus (blue arrows in B) is visualized, accompanied by a significant amount of pericardial effusion (asterisk in B). (C) Late enhancement acquisition using iodinated contrast shows an increased signal of the inferior myocardial wall apical of the pseudoaneurysm on a calculated iodine map (orange arrow) and (D) an extracellular volume map (arrow), indicating myocardial fibrosis. On the iodine map, an increased signal surrounding the aneurysm is visualized (white arrows in C), suggestive of pericardial involvement. CCTA = cardiac computed tomography angiography; ECV = extracellular volume; LV = left ventricle; PA = pseudoaneurysm.

    Article Snippet: Scanning was performed on a first-generation photon-counting detector computed tomography (PCD-CT) scanner (NAEOTOM Alpha, Siemens Healthineers).

    Techniques: Computed Tomography

    Photon-Counting Detector CCTA Photon-counting detector CCTA image demonstrating a pseudoaneurysm of the inferoseptal myocardial wall, occlusion of the right coronary artery (blue arrow), and pericardial effusion (asterisk). CCTA = cardiac computed tomography angiography; PA = pseudoaneurysm.

    Journal: JACC Case Reports

    Article Title: Characterizing a Left Ventricular Pseudoaneurysm With Photon-Counting Detector CT

    doi: 10.1016/j.jaccas.2025.106238

    Figure Lengend Snippet: Photon-Counting Detector CCTA Photon-counting detector CCTA image demonstrating a pseudoaneurysm of the inferoseptal myocardial wall, occlusion of the right coronary artery (blue arrow), and pericardial effusion (asterisk). CCTA = cardiac computed tomography angiography; PA = pseudoaneurysm.

    Article Snippet: Scanning was performed on a first-generation photon-counting detector computed tomography (PCD-CT) scanner (NAEOTOM Alpha, Siemens Healthineers).

    Techniques: Computed Tomography

    Short-Axis Comparison Between CMR and PCD-CT Findings The basal short-axis slices (upper row) show late enhancement surrounding the pseudoaneurysm, while the mid slices (middle row) show late enhancement of the inferior wall below the pseudoaneurysm. The apical slices (lower row) do not show any enhancement of the myocardium. A stack artifact in the PCD-CT images seems to cause a horizontal line of increased ECV in the mid/apical short axis slice. T2-weigted CMR images do not include a hyperintense signal in the infarcted myocardium, indicating the absence of myocardial edema and confirming the chronic stage of the infarction. A hyperintense signal of the pericardium is visible, consistent with active pericarditis. CMR = cardiac magnetic resonance imaging; ECV = extracellular volume; LGE = late gadolinium enhancement; PCD-CT = photon-counting detector computed tomography.

    Journal: JACC Case Reports

    Article Title: Characterizing a Left Ventricular Pseudoaneurysm With Photon-Counting Detector CT

    doi: 10.1016/j.jaccas.2025.106238

    Figure Lengend Snippet: Short-Axis Comparison Between CMR and PCD-CT Findings The basal short-axis slices (upper row) show late enhancement surrounding the pseudoaneurysm, while the mid slices (middle row) show late enhancement of the inferior wall below the pseudoaneurysm. The apical slices (lower row) do not show any enhancement of the myocardium. A stack artifact in the PCD-CT images seems to cause a horizontal line of increased ECV in the mid/apical short axis slice. T2-weigted CMR images do not include a hyperintense signal in the infarcted myocardium, indicating the absence of myocardial edema and confirming the chronic stage of the infarction. A hyperintense signal of the pericardium is visible, consistent with active pericarditis. CMR = cardiac magnetic resonance imaging; ECV = extracellular volume; LGE = late gadolinium enhancement; PCD-CT = photon-counting detector computed tomography.

    Article Snippet: Scanning was performed on a first-generation photon-counting detector computed tomography (PCD-CT) scanner (NAEOTOM Alpha, Siemens Healthineers).

    Techniques: Comparison, Magnetic Resonance Imaging, Computed Tomography