Review



microscopy automation & image analysis software  (MetaMorph Inc)

 
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    MetaMorph Inc microscopy automation & image analysis software
    Microscopy Automation & Image Analysis Software, supplied by MetaMorph Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/automated+image+analysis+algorithm/microscopy+automation+and+image+analysis+software/pmc08203899-29-1-0
    Average 90 stars, based on 1 article reviews
    microscopy automation & image analysis software - by Bioz Stars, 2026-11
    90/100 stars

    Images

    Related Articles

    Microscopy:

    Article Title: High-Resolution C. elegans Imaging Across All Larval Stages.
    Article Snippet: Caenorhabditis elegans has become one of the most widely studied and bestunderstood animal models in biology.. Three features are key to C. elegans' success as a model organism: its invariant cell lineage, transparency, and genetic tractability.. These render it ideal for a diverse range of microscopy-based studies directly in vivo.

    Article Title: A neural tract-inspired conduit for facile, on-demand biopsy of glioblastoma
    Article Snippet: Tiled images were obtained using a Leica semi-confocal microscope fluorescent imaging system, and quantification procedures were performed for DAPI, GFP, and Ku80 antibodies using pre-defined thresholds. .. Images were processed through either Image J or MetaMorph Microscopy Image Analysis Software. ..

    Article Title: Carbene formation as a mechanism for efficient intracellular uptake of cationic antimicrobial carbon acid polymers.
    Article Snippet: .. The fluorescence images were edited by subtracting the background with MetaMorph Microscopy Automation and Image Analysis Software. ..

    Article Title: Dual regulation of IP 3 receptors by IP 3 and PIP 2 controls the transition from local to global Ca 2+ signals.
    Article Snippet: All fluorescence images and image stacks were background-corrected before analysis via subtraction of the fluorescence de- tected from a region outside the cell using MetaMorph Microscopy Automation and Image Analysis Software. .. All fluorescence images and image stacks were background-corrected before analysis via subtraction of the fluorescence de- tected from a region outside the cell using MetaMorph Microscopy Automation and Image Analysis Software. ..

    Article Title: Mutations in Parkinsonism-linked endocytic proteins synaptojanin1 and auxilin have synergistic effects on dopaminergic axonal pathology.
    Article Snippet: .. Image acquisition involved tiling of the entire section using a 20x Air lens, keeping the same laser intensity and exposure for both channels on MetaMorph Microscopy Automation and Image Analysis Software (RRID: SCR_002368). .. Stitched images were then set to the same threshold intensity for each individual channel in Fiji software (Version ImageJ 1.52p/Java 1.8.0_172 (64-bit), RRID: SCR_002285).

    Article Title: Development of Bifunctional, Raman Active Diyne-Girder Stapled α-Helical Peptides.
    Article Snippet: Stapled peptides are a unique class of cyclic αhelical peptides that are conformationally constrained via their amino acid side-chains.. They have been transformative to the field of chemical biology and peptide drug discovery through addressing many of the physicochemical limitations of linear peptides.. However, there are several issues with current chemical strategies to produce stapled peptides.

    Software:

    Article Title: High-Resolution C. elegans Imaging Across All Larval Stages.
    Article Snippet: Caenorhabditis elegans has become one of the most widely studied and bestunderstood animal models in biology.. Three features are key to C. elegans' success as a model organism: its invariant cell lineage, transparency, and genetic tractability.. These render it ideal for a diverse range of microscopy-based studies directly in vivo.

    Article Title: A neural tract-inspired conduit for facile, on-demand biopsy of glioblastoma
    Article Snippet: Tiled images were obtained using a Leica semi-confocal microscope fluorescent imaging system, and quantification procedures were performed for DAPI, GFP, and Ku80 antibodies using pre-defined thresholds. .. Images were processed through either Image J or MetaMorph Microscopy Image Analysis Software. ..

    Article Title: Carbene formation as a mechanism for efficient intracellular uptake of cationic antimicrobial carbon acid polymers.
    Article Snippet: .. The fluorescence images were edited by subtracting the background with MetaMorph Microscopy Automation and Image Analysis Software. ..

    Article Title: Dual regulation of IP 3 receptors by IP 3 and PIP 2 controls the transition from local to global Ca 2+ signals.
    Article Snippet: All fluorescence images and image stacks were background-corrected before analysis via subtraction of the fluorescence de- tected from a region outside the cell using MetaMorph Microscopy Automation and Image Analysis Software. .. All fluorescence images and image stacks were background-corrected before analysis via subtraction of the fluorescence de- tected from a region outside the cell using MetaMorph Microscopy Automation and Image Analysis Software. ..

    Article Title: Mutations in Parkinsonism-linked endocytic proteins synaptojanin1 and auxilin have synergistic effects on dopaminergic axonal pathology.
    Article Snippet: .. Image acquisition involved tiling of the entire section using a 20x Air lens, keeping the same laser intensity and exposure for both channels on MetaMorph Microscopy Automation and Image Analysis Software (RRID: SCR_002368). .. Stitched images were then set to the same threshold intensity for each individual channel in Fiji software (Version ImageJ 1.52p/Java 1.8.0_172 (64-bit), RRID: SCR_002285).

    Article Title: Development of Bifunctional, Raman Active Diyne-Girder Stapled α-Helical Peptides.
    Article Snippet: Stapled peptides are a unique class of cyclic αhelical peptides that are conformationally constrained via their amino acid side-chains.. They have been transformative to the field of chemical biology and peptide drug discovery through addressing many of the physicochemical limitations of linear peptides.. However, there are several issues with current chemical strategies to produce stapled peptides.

    other:

    Article Title: Probing DNA damage sites reveals context-dependent and novel DNA damage response factors
    Article Snippet: Spinning disk z-stacks were acquired using MetaMorph Microscopy Automation & Image Analysis Software.

    Article Title: Dynamin1 long- and short-tail isoforms exploit distinct recruitment and spatial patterns to form endocytic nanoclusters
    Article Snippet: Data Policy information about availability of data All manuscripts must include a data availability statement This statement should provide the following information, where applicable: - Accession codes, unique identifiers, or web links for publicly available datasets - A description of any restrictions on data availability - For clinical datasets or third party data, please ensure that the statement adheres to our policy Frédéric A. Meunier and Merja Joensuu 2 April 2024 TIRF microscopy and super resolution microscopy data (sptPALM) were acquired using Metamorph Microscopy Automation and Image analysis Software, version 7.7.8.

    Analysis:

    Article Title: A neural tract-inspired conduit for facile, on-demand biopsy of glioblastoma
    Article Snippet: Tiled images were obtained using a Leica semi-confocal microscope fluorescent imaging system, and quantification procedures were performed for DAPI, GFP, and Ku80 antibodies using pre-defined thresholds. .. Images were processed through either Image J or MetaMorph Microscopy Image Analysis Software. ..

    Fluorescence:

    Article Title: Carbene formation as a mechanism for efficient intracellular uptake of cationic antimicrobial carbon acid polymers.
    Article Snippet: .. The fluorescence images were edited by subtracting the background with MetaMorph Microscopy Automation and Image Analysis Software. ..

    Article Title: Dual regulation of IP 3 receptors by IP 3 and PIP 2 controls the transition from local to global Ca 2+ signals.
    Article Snippet: All fluorescence images and image stacks were background-corrected before analysis via subtraction of the fluorescence de- tected from a region outside the cell using MetaMorph Microscopy Automation and Image Analysis Software. .. All fluorescence images and image stacks were background-corrected before analysis via subtraction of the fluorescence de- tected from a region outside the cell using MetaMorph Microscopy Automation and Image Analysis Software. ..



    Similar Products

    90
    Thermo Fisher automated image analysis algorithm
    Automated Image Analysis Algorithm, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/automated+image+analysis+algorithm/pmc11801715-262-5-4
    Average 90 stars, based on 1 article reviews
    automated image analysis algorithm - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc automated image analysis algorithm
    Automated Image Analysis Algorithm, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/automated+image+analysis+algorithm/pm38781661-52-17-22
    Average 90 stars, based on 1 article reviews
    automated image analysis algorithm - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc semi-automated image analysis algorithm
    Semi Automated Image Analysis Algorithm, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/automated+image+analysis+algorithm/pm37778466-122-14-20
    Average 90 stars, based on 1 article reviews
    semi-automated image analysis algorithm - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Visiopharm AS automated estrogen receptor (er) digital imaging analysis (dia) algorithm
    Automated workflow of ER IHC digital imaging analysis <t>(DIA)</t> <t>using</t> <t>Visiopharm</t> coupled with whole slide images (WSI) in the Philips Image Management System (IMS). (A) Downloading case metadata for 1 ER IHC slide in Philips Imaging Managing System. (B) Streaming whole slide image of ER IHC slide by opening its metadata file in Visiopharm. (C) Selecting tumor detection and ER digital imaging analysis algorithms in Visiopharm app center. (D) Analyzing ER results using automated ER digital imaging analsysis algorithm.
    Automated Estrogen Receptor (Er) Digital Imaging Analysis (Dia) Algorithm, supplied by Visiopharm AS, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/automated+image+analysis+algorithm/automated+estrogen+receptor++er++digital+imaging+analysis++dia++algorithm/pmc09577060-29-2-1
    Average 90 stars, based on 1 article reviews
    automated estrogen receptor (er) digital imaging analysis (dia) algorithm - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Visiopharm AS automated image analysis algorithms
    Automated workflow of ER IHC digital imaging analysis <t>(DIA)</t> <t>using</t> <t>Visiopharm</t> coupled with whole slide images (WSI) in the Philips Image Management System (IMS). (A) Downloading case metadata for 1 ER IHC slide in Philips Imaging Managing System. (B) Streaming whole slide image of ER IHC slide by opening its metadata file in Visiopharm. (C) Selecting tumor detection and ER digital imaging analysis algorithms in Visiopharm app center. (D) Analyzing ER results using automated ER digital imaging analsysis algorithm.
    Automated Image Analysis Algorithms, supplied by Visiopharm AS, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/automated+image+analysis+algorithm/automated+image+analysis+algorithms/pmc09026790-106-30-14
    Average 90 stars, based on 1 article reviews
    automated image analysis algorithms - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Aperio Technologies automated image analysis algorithm color deconvolution
    Digital pathology imaging and measurement of lymph node stroma in HL and NHL. Slides of hematoxilin-eosin (HE, representative cases in Panel ( A )) or Mallory trichrome staining (representative cases in Panel ( B )) from LN sections of patients with HL ( n = 11), FL1-2 ( n = 6), FL3A ( n = 8), DLBCL ( n = 6), compared with 9 LDN, were subjected to Digital Pathology Imaging. Panel ( C ). HE sections were analyzed with the Genie software (right images in Panel ( A )) and the percentage area of stromal compartment per slide was calculated, adjusted to total tissue area in the image analyzed. Data are expressed as a percentage of green pseudocolor (stromal) areas and are the mean ± SEM of the indicated number of cases for each histological type. * p < 0.05 vs. LDN, FL1-2 and FL3A. Panel ( D ): digital images of Mallory trichrome stained sections were analyzed with an automated image analysis algorithm for color <t>deconvolution</t> (right images in Panel ( B )) and collagen areas quantified by the Image Scope software. Data are expressed as percentage of blue (collagen) areas and are the mean ± SEM of the indicated number of cases for each histological type. * p < 0.005 vs. LDN, FL1-2 and FL3A.
    Automated Image Analysis Algorithm Color Deconvolution, supplied by Aperio Technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/automated+image+analysis+algorithm/automated+image+analysis+algorithm+color+deconvolution/pmc08750937-68-18-27
    Average 90 stars, based on 1 article reviews
    automated image analysis algorithm color deconvolution - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Visikol inc algorithm-based automated image analysis
    Digital pathology imaging and measurement of lymph node stroma in HL and NHL. Slides of hematoxilin-eosin (HE, representative cases in Panel ( A )) or Mallory trichrome staining (representative cases in Panel ( B )) from LN sections of patients with HL ( n = 11), FL1-2 ( n = 6), FL3A ( n = 8), DLBCL ( n = 6), compared with 9 LDN, were subjected to Digital Pathology Imaging. Panel ( C ). HE sections were analyzed with the Genie software (right images in Panel ( A )) and the percentage area of stromal compartment per slide was calculated, adjusted to total tissue area in the image analyzed. Data are expressed as a percentage of green pseudocolor (stromal) areas and are the mean ± SEM of the indicated number of cases for each histological type. * p < 0.05 vs. LDN, FL1-2 and FL3A. Panel ( D ): digital images of Mallory trichrome stained sections were analyzed with an automated image analysis algorithm for color <t>deconvolution</t> (right images in Panel ( B )) and collagen areas quantified by the Image Scope software. Data are expressed as percentage of blue (collagen) areas and are the mean ± SEM of the indicated number of cases for each histological type. * p < 0.005 vs. LDN, FL1-2 and FL3A.
    Algorithm Based Automated Image Analysis, supplied by Visikol inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/automated+image+analysis+algorithm/algorithm+based+automated+image+analysis/pmc08592477-86-10-6
    Average 90 stars, based on 1 article reviews
    algorithm-based automated image analysis - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    MuscleSound LLC automated image analysis algorithm
    Digital pathology imaging and measurement of lymph node stroma in HL and NHL. Slides of hematoxilin-eosin (HE, representative cases in Panel ( A )) or Mallory trichrome staining (representative cases in Panel ( B )) from LN sections of patients with HL ( n = 11), FL1-2 ( n = 6), FL3A ( n = 8), DLBCL ( n = 6), compared with 9 LDN, were subjected to Digital Pathology Imaging. Panel ( C ). HE sections were analyzed with the Genie software (right images in Panel ( A )) and the percentage area of stromal compartment per slide was calculated, adjusted to total tissue area in the image analyzed. Data are expressed as a percentage of green pseudocolor (stromal) areas and are the mean ± SEM of the indicated number of cases for each histological type. * p < 0.05 vs. LDN, FL1-2 and FL3A. Panel ( D ): digital images of Mallory trichrome stained sections were analyzed with an automated image analysis algorithm for color <t>deconvolution</t> (right images in Panel ( B )) and collagen areas quantified by the Image Scope software. Data are expressed as percentage of blue (collagen) areas and are the mean ± SEM of the indicated number of cases for each histological type. * p < 0.005 vs. LDN, FL1-2 and FL3A.
    Automated Image Analysis Algorithm, supplied by MuscleSound LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/automated+image+analysis+algorithm/automated+image+analysis+algorithm/pmc08104451-114-10-16
    Average 90 stars, based on 1 article reviews
    automated image analysis algorithm - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc automated image-analysis algorithm
    Digital pathology imaging and measurement of lymph node stroma in HL and NHL. Slides of hematoxilin-eosin (HE, representative cases in Panel ( A )) or Mallory trichrome staining (representative cases in Panel ( B )) from LN sections of patients with HL ( n = 11), FL1-2 ( n = 6), FL3A ( n = 8), DLBCL ( n = 6), compared with 9 LDN, were subjected to Digital Pathology Imaging. Panel ( C ). HE sections were analyzed with the Genie software (right images in Panel ( A )) and the percentage area of stromal compartment per slide was calculated, adjusted to total tissue area in the image analyzed. Data are expressed as a percentage of green pseudocolor (stromal) areas and are the mean ± SEM of the indicated number of cases for each histological type. * p < 0.05 vs. LDN, FL1-2 and FL3A. Panel ( D ): digital images of Mallory trichrome stained sections were analyzed with an automated image analysis algorithm for color <t>deconvolution</t> (right images in Panel ( B )) and collagen areas quantified by the Image Scope software. Data are expressed as percentage of blue (collagen) areas and are the mean ± SEM of the indicated number of cases for each histological type. * p < 0.005 vs. LDN, FL1-2 and FL3A.
    Automated Image Analysis Algorithm, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/automated+image+analysis+algorithm/10__1103_slash_physrevapplied__12__064019-76-30-34
    Average 90 stars, based on 1 article reviews
    automated image-analysis algorithm - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    Automated workflow of ER IHC digital imaging analysis (DIA) using Visiopharm coupled with whole slide images (WSI) in the Philips Image Management System (IMS). (A) Downloading case metadata for 1 ER IHC slide in Philips Imaging Managing System. (B) Streaming whole slide image of ER IHC slide by opening its metadata file in Visiopharm. (C) Selecting tumor detection and ER digital imaging analysis algorithms in Visiopharm app center. (D) Analyzing ER results using automated ER digital imaging analsysis algorithm.

    Journal: Journal of Pathology Informatics

    Article Title: Integrating and validating automated digital imaging analysis of estrogen receptor immunohistochemistry in a fully digital workflow for clinical use

    doi: 10.1016/j.jpi.2022.100122

    Figure Lengend Snippet: Automated workflow of ER IHC digital imaging analysis (DIA) using Visiopharm coupled with whole slide images (WSI) in the Philips Image Management System (IMS). (A) Downloading case metadata for 1 ER IHC slide in Philips Imaging Managing System. (B) Streaming whole slide image of ER IHC slide by opening its metadata file in Visiopharm. (C) Selecting tumor detection and ER digital imaging analysis algorithms in Visiopharm app center. (D) Analyzing ER results using automated ER digital imaging analsysis algorithm.

    Article Snippet: The Visiopharm automated estrogen receptor (ER) digital imaging analysis (DIA) algorithm assesses digitized ER immunohistochemistry (IHC) by segmenting tumor nuclei and detecting stained nuclei automatically.

    Techniques: Imaging

    Comparison between original reads of estrogen receptor immunohistochemistry positivity with digital imaging analysis’ reads and pathologists’ reads.

    Journal: Journal of Pathology Informatics

    Article Title: Integrating and validating automated digital imaging analysis of estrogen receptor immunohistochemistry in a fully digital workflow for clinical use

    doi: 10.1016/j.jpi.2022.100122

    Figure Lengend Snippet: Comparison between original reads of estrogen receptor immunohistochemistry positivity with digital imaging analysis’ reads and pathologists’ reads.

    Article Snippet: The Visiopharm automated estrogen receptor (ER) digital imaging analysis (DIA) algorithm assesses digitized ER immunohistochemistry (IHC) by segmenting tumor nuclei and detecting stained nuclei automatically.

    Techniques: Comparison, Immunohistochemistry, Imaging

    Six cases with discordant estrogen receptor results between digital imaging analysis and original reads.

    Journal: Journal of Pathology Informatics

    Article Title: Integrating and validating automated digital imaging analysis of estrogen receptor immunohistochemistry in a fully digital workflow for clinical use

    doi: 10.1016/j.jpi.2022.100122

    Figure Lengend Snippet: Six cases with discordant estrogen receptor results between digital imaging analysis and original reads.

    Article Snippet: The Visiopharm automated estrogen receptor (ER) digital imaging analysis (DIA) algorithm assesses digitized ER immunohistochemistry (IHC) by segmenting tumor nuclei and detecting stained nuclei automatically.

    Techniques: Imaging, Staining

    Digital pathology imaging and measurement of lymph node stroma in HL and NHL. Slides of hematoxilin-eosin (HE, representative cases in Panel ( A )) or Mallory trichrome staining (representative cases in Panel ( B )) from LN sections of patients with HL ( n = 11), FL1-2 ( n = 6), FL3A ( n = 8), DLBCL ( n = 6), compared with 9 LDN, were subjected to Digital Pathology Imaging. Panel ( C ). HE sections were analyzed with the Genie software (right images in Panel ( A )) and the percentage area of stromal compartment per slide was calculated, adjusted to total tissue area in the image analyzed. Data are expressed as a percentage of green pseudocolor (stromal) areas and are the mean ± SEM of the indicated number of cases for each histological type. * p < 0.05 vs. LDN, FL1-2 and FL3A. Panel ( D ): digital images of Mallory trichrome stained sections were analyzed with an automated image analysis algorithm for color deconvolution (right images in Panel ( B )) and collagen areas quantified by the Image Scope software. Data are expressed as percentage of blue (collagen) areas and are the mean ± SEM of the indicated number of cases for each histological type. * p < 0.005 vs. LDN, FL1-2 and FL3A.

    Journal: Cancers

    Article Title: Lysyl-Oxidase Dependent Extracellular Matrix Stiffness in Hodgkin Lymphomas: Mechanical and Topographical Evidence

    doi: 10.3390/cancers14010259

    Figure Lengend Snippet: Digital pathology imaging and measurement of lymph node stroma in HL and NHL. Slides of hematoxilin-eosin (HE, representative cases in Panel ( A )) or Mallory trichrome staining (representative cases in Panel ( B )) from LN sections of patients with HL ( n = 11), FL1-2 ( n = 6), FL3A ( n = 8), DLBCL ( n = 6), compared with 9 LDN, were subjected to Digital Pathology Imaging. Panel ( C ). HE sections were analyzed with the Genie software (right images in Panel ( A )) and the percentage area of stromal compartment per slide was calculated, adjusted to total tissue area in the image analyzed. Data are expressed as a percentage of green pseudocolor (stromal) areas and are the mean ± SEM of the indicated number of cases for each histological type. * p < 0.05 vs. LDN, FL1-2 and FL3A. Panel ( D ): digital images of Mallory trichrome stained sections were analyzed with an automated image analysis algorithm for color deconvolution (right images in Panel ( B )) and collagen areas quantified by the Image Scope software. Data are expressed as percentage of blue (collagen) areas and are the mean ± SEM of the indicated number of cases for each histological type. * p < 0.005 vs. LDN, FL1-2 and FL3A.

    Article Snippet: Layers of each virtual slide annotation were created manually, selecting the whole area, and analyzed with the automated image analysis algorithm color deconvolution (Aperio software version 9.1, Aperio Technologies, Nussloch GmbH, Wetzlar, Germany).

    Techniques: Imaging, Staining, Software