Review



aspheric hydrophobic acrylic iols acrysof sn60wf  (alcon inc)

 
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    alcon inc aspheric hydrophobic acrylic iols acrysof sn60wf
    Scatterplot shows the nominal power vs measured power for the Appasamy APPALENS 207 (orange) and Alcon <t>SN60WF</t> (purple) <t>IOLs.</t>
    Aspheric Hydrophobic Acrylic Iols Acrysof Sn60wf, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/acrysof/acrysof+sn60wf/pmc11146172-48-20-25
    Average 90 stars, based on 1 article reviews
    aspheric hydrophobic acrylic iols acrysof sn60wf - by Bioz Stars, 2026-11
    90/100 stars

    Images

    1) Product Images from "Peripheral defocus of monofocal intraocular lenses"

    Article Title: Peripheral defocus of monofocal intraocular lenses

    Journal: Journal of Cataract and Refractive Surgery

    doi: 10.1097/j.jcrs.0000000000001441

    Scatterplot shows the nominal power vs measured power for the Appasamy APPALENS 207 (orange) and Alcon SN60WF (purple) IOLs.
    Figure Legend Snippet: Scatterplot shows the nominal power vs measured power for the Appasamy APPALENS 207 (orange) and Alcon SN60WF (purple) IOLs.

    Techniques Used:

    Scatterplot shows the (A, B) measured power and (C, D) relative peripheral defocus (difference between off-axis and on-axis power) for each IOL as a function of the delivery angle for (A, C) Appasamy APPALENS 207 and (B, D) Alcon SN60WF IOLs. For clarity, error bars are not shown. The range (maximum minus minimum) of repeated measurements was within 1.5 D for the Alcon SN60WF and within 0.8 D for the Appasamy APPALENS 207, except for the 20-degree measurement of the 21.5 D Appasamy APPALENS 207 IOL, where the range was 3.0 D.
    Figure Legend Snippet: Scatterplot shows the (A, B) measured power and (C, D) relative peripheral defocus (difference between off-axis and on-axis power) for each IOL as a function of the delivery angle for (A, C) Appasamy APPALENS 207 and (B, D) Alcon SN60WF IOLs. For clarity, error bars are not shown. The range (maximum minus minimum) of repeated measurements was within 1.5 D for the Alcon SN60WF and within 0.8 D for the Appasamy APPALENS 207, except for the 20-degree measurement of the 21.5 D Appasamy APPALENS 207 IOL, where the range was 3.0 D.

    Techniques Used:

    The measured defocus, predicted tangential, and sagittal defocus at 30 degrees, 20 degrees, and 10 degrees plotted against the IOL power for Appasamy APPALENS 207 and Alcon SN60WF IOLs. For the measured values, the average of the measurements recorded at ±30 degrees, ±20 degrees, and ±10 degrees was used.
    Figure Legend Snippet: The measured defocus, predicted tangential, and sagittal defocus at 30 degrees, 20 degrees, and 10 degrees plotted against the IOL power for Appasamy APPALENS 207 and Alcon SN60WF IOLs. For the measured values, the average of the measurements recorded at ±30 degrees, ±20 degrees, and ±10 degrees was used.

    Techniques Used:

    Related Articles

    other:

    Article Title: Accuracy of 12 IOL power calculation formulas in highly myopic eyes.
    Article Snippet: In all cases, one of the following IOL models was implanted: SN60WF, MN60MA (Alcon Laboratories, Inc.), or EyeCee®One (Bausch + Lomb, Inc.).

    Article Title: A new method for analyzing glistenings in hydrophobic acrylic intraocular lenses
    Article Snippet: In this experimental study, 25 hydrophobic acrylic IOLs from 5 different IOL models such as AcrySof SN60WF (Expiry Date: 2025-09-30), AcrySof MA60 AC (Expiry Date: 2025-12-15), Clareon CNA0T0 (Expiry Date: 2024-01-20) (Alcon Laboratory, Forth Worth, USA), PY60AD (Expiry Date: 2024-02-29) (Hoya, Tokyo, Japan) and Vivinex XY1 (Expiry Date: 2023-11-30) (Hoya, Tokyo, Japan) were used.

    Article Title: Timing of the modified yamane technique in complicated cataract surgery: same session or second session?
    Article Snippet: differences were observed between the two groups in relation to visual acuity, refraction measurements, or intraocular pressure values(p > 0.05 for all).. Central macular thickness was measured as 274 ± 18 microns(range:236–291 microns) in group P and 254 ± 11 microns (range:229–272 microns) in group S(p = 0.02).In the early postoperative period (< 1 month),cystoid macular edema occurred in two cases(16.6%) in group P, while one case(8.3%) of increased intraocular pressure and one case(8.3%) of severe corneal edema were observed.. In group S, cystoid macular edema occurred in one case(3.4%).No complications were detected in either group during the late postoperative period.

    Article Title: Clinical Outcomes and in vivo Aberrometry Following the Implantation of a Monofocal IOL with Positive Asphericity
    Article Snippet: For AcrySof SN60WF IOL, the mean ocular SA have been reported to be 0.03 ± 0.05 μm for 5.0 mm pupil measured with LADARWave aberrometer (Alcon Laboratories).

    Control:

    Article Title: Effectiveness and safety of a hydrophobic aspheric monofocal intraocular lens with molding process for cataract surgery
    Article Snippet: .. Subjects were randomly assigned to receive either the aspheric monofocal IOL (SM60AS, Henan Simedice Biotechnology Co. Ltd., Zhengzhou, China) or the control IOL (SN60WF Alcon Laboratories Inc.). ..

    Injection:

    Article Title: Corneal Endothelial Changes After Phacoemulsification Using the Eight-Chop Technique in Diabetic Eyes.
    Article Snippet: .. The ophthalmic viscosurgical device was injected, and a foldable IOL (Acrysof® MN60AC; Alcon Laboratories, Inc., Fort Worth, TX, USA), with polymethyl methacrylate haptics, was placed into the capsular bag via injection. ..

    Article Title: Impact of residual ophthalmic viscosurgical device behind intraocular lens on postoperative intraocular pressure and refractive outcomes in cataract surgery.
    Article Snippet: time (p = 0.01).. A positive correlation was observed between OVD reduction and IOP decrease from days 1 to 3 (p = 0.01, r = 0.581) and days 1 to 5 (p = 0.017, r = 0.432).. Additionally, a significant association was found between OVD reduction and myopic shift from days 3 to 5 (p = 0.014, r = 0.444).

    Article Title: Corneal Endothelial Changes After Phacoemulsification Using the Eight-Chop Technique in Diabetic Eyes
    Article Snippet: .. The ophthalmic viscosurgical device was injected, and a foldable IOL (Acrysof ® MN60AC; Alcon Laboratories, Inc., Fort Worth, TX, USA), with polymethyl methacrylate haptics, was placed into the capsular bag via injection. ..



    Similar Products

    86
    Vivity Labs Inc acrysof iq vivity
    Acrysof Iq Vivity, supplied by Vivity Labs Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/acrysof/acrysof+iq+vivity/pmc13170592-153-6-8
    Average 86 stars, based on 1 article reviews
    acrysof iq vivity - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    86
    Vivity Labs Inc acrysof vivity
    Acrysof Vivity, supplied by Vivity Labs Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/acrysof/acrysof+iq+vivity/pmc13142695-119-17-18
    Average 86 stars, based on 1 article reviews
    acrysof vivity - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    86
    Vivity Labs Inc acrysof iq vivity iol
    Acrysof Iq Vivity Iol, supplied by Vivity Labs Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/acrysof/acrysof+iq+vivity/pmc13123711-198-3-5
    Average 86 stars, based on 1 article reviews
    acrysof iq vivity iol - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    90
    alcon inc diffractive aspheric trifocal lenses acrysof iq panoptix tfnt00
    Diffractive Aspheric Trifocal Lenses Acrysof Iq Panoptix Tfnt00, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/acrysof/tfnt00/pmc12277180-44-12-16
    Average 90 stars, based on 1 article reviews
    diffractive aspheric trifocal lenses acrysof iq panoptix tfnt00 - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Vivity Labs Inc toric iols acrysof
    Toric Iols Acrysof, supplied by Vivity Labs Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/acrysof/acrysof+iq+vivity+iol/pm40661044-29-14-15
    Average 90 stars, based on 1 article reviews
    toric iols acrysof - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Vivity Labs Inc acrysof® iq vivity® intraocular lens
    Acrysof® Iq Vivity® Intraocular Lens, supplied by Vivity Labs Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/acrysof/acrysof+iq+vivity+iol/pm40661044-158-7-11
    Average 90 stars, based on 1 article reviews
    acrysof® iq vivity® intraocular lens - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results