Review




Structured Review

Tecplot Inc 3d visualization program
3d Visualization Program, supplied by Tecplot Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+immersive+visualization+program/3d+visualization+program/pm27989592-131-5-11
Average 90 stars, based on 1 article reviews
3d visualization program - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

other:

Article Title: COMETS2: An advanced MATLAB toolbox for the numerical analysis of electric fields generated by transcranial direct current stimulation.
Article Snippet: Background: Since there is no way to measure electric current generated by transcranial direct current stimulation (tDCS) inside the human head through in vivo experiments, numerical analysis based on the finite element method has been widely used to estimate the electric field inside the head.. In 2013, we released a MATLAB toolbox named COMETS, which has been used by a number of groups and has helped researchers to gain insight into the electric field distribution during stimulation.. The aim of this study was to develop an advanced MATLAB toolbox, named COMETS2, for the numerical analysis of the electric field generated by tDCS.



Similar Products

90
syGlass Inc 3d immersive visualization program
Experimental design for cell counting using <t>3D</t> virtual reality. (A) Serial sections containing MNTB from Cre;Ai9 mice were stained with cell-specific antibodies for neurons (Map2), astrocytes (Aldh1L1), oligodendrocytes (Sox10) and microglia (Iba1), in an alternating manner, along with DAPI. These slices were imaged with a 40× objective and tiled. The MNTB is outlined in white in each section and the midline is indicated by a dashed white line. Scale bar = 100 μm. (B) The MNTB was cropped from the larger image and imported <t>into</t> <t>syGlass</t> for cell counting in 3D virtual reality. The solid and dashed white lines demarcate cut planes that were rotated to generate the 3D view in C (arrow). Scale bar = 50 μm. (C) Rotated view of part of MNTB to illustrate 3D view for cell counting. Counting dots were placed onto the nuclei. White dots indicate incomplete (sectioned) nuclei in the first slice of the z-stack. These were excluded from analysis, but incomplete nuclei in the bottom slice were counted and included in the analysis. Red dots indicate cells that were counted. Note that cells throughout the entire MNTB (panel B) were counted.
3d Immersive Visualization Program, supplied by syGlass Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+immersive+visualization+program/virtual+reality+software/pmc09245928-234-2-1
Average 90 stars, based on 1 article reviews
3d immersive visualization program - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Experimental design for cell counting using 3D virtual reality. (A) Serial sections containing MNTB from Cre;Ai9 mice were stained with cell-specific antibodies for neurons (Map2), astrocytes (Aldh1L1), oligodendrocytes (Sox10) and microglia (Iba1), in an alternating manner, along with DAPI. These slices were imaged with a 40× objective and tiled. The MNTB is outlined in white in each section and the midline is indicated by a dashed white line. Scale bar = 100 μm. (B) The MNTB was cropped from the larger image and imported into syGlass for cell counting in 3D virtual reality. The solid and dashed white lines demarcate cut planes that were rotated to generate the 3D view in C (arrow). Scale bar = 50 μm. (C) Rotated view of part of MNTB to illustrate 3D view for cell counting. Counting dots were placed onto the nuclei. White dots indicate incomplete (sectioned) nuclei in the first slice of the z-stack. These were excluded from analysis, but incomplete nuclei in the bottom slice were counted and included in the analysis. Red dots indicate cells that were counted. Note that cells throughout the entire MNTB (panel B) were counted.

Journal: Developmental neurobiology

Article Title: Glial Cell Expansion Coincides with Neural Circuit Formation in the Developing Auditory Brainstem

doi: 10.1002/dneu.22633

Figure Lengend Snippet: Experimental design for cell counting using 3D virtual reality. (A) Serial sections containing MNTB from Cre;Ai9 mice were stained with cell-specific antibodies for neurons (Map2), astrocytes (Aldh1L1), oligodendrocytes (Sox10) and microglia (Iba1), in an alternating manner, along with DAPI. These slices were imaged with a 40× objective and tiled. The MNTB is outlined in white in each section and the midline is indicated by a dashed white line. Scale bar = 100 μm. (B) The MNTB was cropped from the larger image and imported into syGlass for cell counting in 3D virtual reality. The solid and dashed white lines demarcate cut planes that were rotated to generate the 3D view in C (arrow). Scale bar = 50 μm. (C) Rotated view of part of MNTB to illustrate 3D view for cell counting. Counting dots were placed onto the nuclei. White dots indicate incomplete (sectioned) nuclei in the first slice of the z-stack. These were excluded from analysis, but incomplete nuclei in the bottom slice were counted and included in the analysis. Red dots indicate cells that were counted. Note that cells throughout the entire MNTB (panel B) were counted.

Article Snippet: The syGlass 3D immersive visualization program was used to perform cell counts because it enables rapid and accurate assessment of sectioned DAPI-labeled nuclei at the edge of the first image plane , and it permits accurate assessment of spatial association of markers with DAPI in three dimensions.

Techniques: Cell Counting, Staining